Effect of Voxel Size of Micro-CT on the Assessment of Root Canal Preparation

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.creatorPinto, Jader Camilo-
Autor(es): dc.creatorLucas-Oliveira, Everton-
Autor(es): dc.creatorBonagamba, Tito Jose-
Autor(es): dc.creatorGuerreiro-Tanomaru, Juliane Maria-
Autor(es): dc.creatorTanomaru-Filho, Mario-
Data de aceite: dc.date.accessioned2025-08-21T22:06:28Z-
Data de disponibilização: dc.date.available2025-08-21T22:06:28Z-
Data de envio: dc.date.issued2023-07-29-
Data de envio: dc.date.issued2023-07-29-
Data de envio: dc.date.issued2023-05-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.15517/ijds.2023.53811-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/247440-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/247440-
Descrição: dc.descriptionThe aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on evaluation of root canal preparation using rotary heat-treated nickel-titanium files. Curved mesial root canals of mandibular molars were prepared using ProDesign Logic 30/.05 (PDL) or HyFlex EDM 25/.08 (HEDM) (n=12). The specimens were scanned using micro-CT with 5μm of voxel size before and after root canal preparation. Images with sub-resolution of 10 and 20μm voxel sizes were obtained. The percentage of volume increase, debris and uninstrumented root canal surface were analyzed in the different voxel sizes. Data were compared using unpaired Student’s t-test and ANOVA statistical tests (α=0.05). No differences were observed for percentage of volume increase, debris and instrumented surface between the root canals prepared by PDL and HEDM (p>0.05). Both systems promoted higher percentage of debris in the apical third compared to the middle third (p<0.05). After instrumentation using PDL the percentage of uninstrumented surface was highr in the apical third than middle third only when analysis were performed at 5µm (p<0.05). When comparing the different voxel sizes (5,10 or 20µm), both groups showed different means for the variables, with no significant difference (p>0.05). PDL and HEDM had similar root canal preparation capacity. Micro-CT images using different voxel sizes did not influence the results of volume increase and debris evaluation. However, images at 5µm showed greater accuracy to evaluate the percentage of uninstrumented surfaces.-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
Descrição: dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
Descrição: dc.descriptionDepartment of Restorative Dentistry Sao Paulo State University (UNESP) School of Dentistry, SP-
Descrição: dc.descriptionSao Carlos Institute of Physics University of Sao Paulo, PO Box 369, SP-
Descrição: dc.descriptionDepartment of Restorative Dentistry Sao Paulo State University (UNESP) School of Dentistry, SP-
Descrição: dc.descriptionCAPES: 001-
Descrição: dc.descriptionFAPESP: 2018/19665-6-
Formato: dc.format93-102-
Idioma: dc.languageen-
Relação: dc.relationOdovtos - International Journal of Dental Sciences-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDental pulp cavity-
Palavras-chave: dc.subjectDentin-
Palavras-chave: dc.subjectEndodontics-
Palavras-chave: dc.subjectRoot canal-
Palavras-chave: dc.subjectRoot canal preparation-
Palavras-chave: dc.subjectX-ray microtomography-
Título: dc.titleEffect of Voxel Size of Micro-CT on the Assessment of Root Canal Preparation-
Título: dc.titleEfecto del tamaño de vóxel de micro-CT en la evaluación de la preparación del conducto radicular-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.