Comparison of Four Arteries for Invasive Blood Pressure Measurements and Dixtal 2010 Oscillometric Values in Horses Anesthetized With Isoflurane: Does the Artery Matter?

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorAuburn University-
Autor(es): dc.creatorMidon, Monica-
Autor(es): dc.creatorYamada, Diego I.-
Autor(es): dc.creatorZangirolami Filho, Darcio-
Autor(es): dc.creatorSimionato, Giulia C.-
Autor(es): dc.creatorFeringer Junior, Walter H.-
Autor(es): dc.creatorConde, Gabriel-
Autor(es): dc.creatorHofmeister, Erik H.-
Data de aceite: dc.date.accessioned2025-08-21T15:15:48Z-
Data de disponibilização: dc.date.available2025-08-21T15:15:48Z-
Data de envio: dc.date.issued2023-07-29-
Data de envio: dc.date.issued2023-07-29-
Data de envio: dc.date.issued2023-01-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1016/j.jevs.2023.104219-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/246670-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/246670-
Descrição: dc.descriptionThis study evaluated the agreement between invasive blood pressure (IBP) values measured in three different arteries and by an oscillometric device (NIBP) with the ones from the transverse facial artery (FA). Six horses (424.2 ± 40.7 kg) were sedated with xylazine (0.6 mg/kg IV), induced with ketamine (2 mg/kg IV) and midazolam (0.1 mg/kg IV), and maintained with isoflurane (1.2 MAC) for 90 minutes in lateral recumbency. FA, auricular artery (AA), lateral digital artery (LDA), and metatarsal artery (MA) were catheterized, and a standard adult cuff was placed on the tail. IBP and NIBP values were recorded at 30, 45, 60, 75, and 90 minutes of anesthesia. Data were analyzed with Shapiro-Wilk and Repeated-Measures Bland-Altman. Values for FA (mm Hg) were 85.4 ± 10.3 for SAP, 70.6 ± 9.3 for MAP, and 58.5 ± 9.5 for DAP. Mean bias and 95% Limit of agreement (LOA) for AA were -1.7 (-29.0 to 25.6), 2.2 (-18.4 to 22.9), 1.9 (-18.2 to 22.0), for LDA: 1.4 (-25.1 to 27.8), 2.9 (-19.3 to 25.0), 2.3 (-18.4 to 22.9), for MA: -3.2 (-28.3 to 22.0), 2.7 (-16.6 to 22.1), 4.9 (-13.8 to 22.2), and for NIBP: -5.7 (-28.3 to 16.9), 7.9 (-9.5 to 25.3), 17.2 (-2.4 to 36.8), for SAP, MAP and DAP respectively. There is a reasonable bias for IBP values among the arteries evaluated, however a wide LOA, demonstrating the arteries are not interchangeable. NIBP method from Dixtal 2010 results in inaccurate blood pressure values in horses.-
Descrição: dc.descriptionSchool of Agrarian and Veterinary Science – FCAV Sao Paulo State University - UNESP, São Paulo-
Descrição: dc.descriptionDepartment of Clinical Sciences College of Veterinary Medicine Auburn University-
Descrição: dc.descriptionSchool of Agrarian and Veterinary Science – FCAV Sao Paulo State University - UNESP, São Paulo-
Idioma: dc.languageen-
Relação: dc.relationJournal of Equine Veterinary Science-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectAnesthesia-
Palavras-chave: dc.subjectBlood pressure-
Palavras-chave: dc.subjectEquine-
Palavras-chave: dc.subjectMonitoring-
Título: dc.titleComparison of Four Arteries for Invasive Blood Pressure Measurements and Dixtal 2010 Oscillometric Values in Horses Anesthetized With Isoflurane: Does the Artery Matter?-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.