Avaliação da variação da concentração da água ozonizada potável e de injeção coletadas na seringa tríplice do equipo e da unidade auxiliar em relação ao tempo de armazenamento em reservatório de cadeira odontológica

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorScarso Filho, José-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorCamargo, Mario Cezar Pereira de-
Data de aceite: dc.date.accessioned2025-08-21T19:30:37Z-
Data de disponibilização: dc.date.available2025-08-21T19:30:37Z-
Data de envio: dc.date.issued2023-06-12-
Data de envio: dc.date.issued2023-06-12-
Data de envio: dc.date.issued2023-02-28-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/244007-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/244007-
Descrição: dc.descriptionO oxigênio é um elemento químico gasoso e estável que pode ser modificado para uma forma alotrópica, sendo chamado de ozônio, apresentando propriedades terapêuticas, mas com pouca estabilidade. Esta propriedade está dentro da técnica chamada de “oxigênio-ozônio terapia” e seu mecanismo de ação é estabelecido através do princípio da oxidação, que promove no organismo uma reação anti-oxidativa, desenvolvendo uma incrível e versátil cascata de eventos derivados do ozônio (ROS). Uma das maneiras de se utilizar o ozônio é através da água que após saturar modifica-se para água ozonizada e a concentração é dependente da concentração de ozônio no gerador, tempo, qualidade (pureza da água) e temperatura da água (menor agitação molecular). Com ênfase na qualidade da água, estudos enfatizam o uso da água de injeção (bidestilada) para melhor saturação do ozônio, mas representa um aumento no custo operacional significativo em comparação a água potável, utilizada na refrigeração dos instrumentos rotatórios. Diante deste grande campo de atuação, traçando um projeto de utilização do veículo “água ozonizada”, no qual todo o processo de refrigeração dos instrumentos rotatórios é feito por meio desta, este estudo teve como objetivo avaliar a variação da concentração da água gelada potável e de injeção coletadas da seringa tríplice do equipo e da seringa tríplice da unidade auxiliar em relação ao tempo para estabelecer se é possível utilizar água potável para fins terapêuticos, durante tratamentos odontológicos, com menor custo operacional. Com base nos achados deste estudo preliminar, aplicado em condições de reprodutibilidade clínica, estabeleceu-se que os dados obtidos, avaliados pelos testes de ANOVA, rejeitou a hipótese H01, não havendo diferença significativa entre a concentração de água ozonizada potável e de injeção coletadas na seringa tríplice (P< 0.05), sendo possível utilizar água potável para fins terapêuticos, durante tratamentos odontológicos, com menor custo operacional. Concluiu-se também que a concentração da água ozonizada diminui em função do tempo na cadeira odontológica em todos os grupos testados. Além disso, diante das médias de concentrações de água ozonizada obtidas conclui-se que sua melhor via de obtenção é a seringa tríplice da unidade auxiliar, aceitando H02.-
Descrição: dc.descriptionOxygen is a gaseous and stable chemical element that can be modified to an allotropic form, being called ozone, presenting therapeutic properties, but with little stability. This property is within the technique called “oxygen-ozone therapy” and its mechanism of action is established through the principle of oxidation, which promotes an anti-oxidative reaction in the body, developing an incredible and versatile cascade of ozone-derived events (ROS). One of the ways to use ozone is through water which, after saturation, changes to ozonized water and the concentration is dependent on the ozone concentration in the generator, time, quality (water purity) and water temperature (lower molecular agitation). With an emphasis on water quality, studies emphasize the use of injection water (double-distilled) for better ozone saturation, but it represents a significant increase in operational cost compared to potable water, used to cool rotary instruments. In view of this large field of activity, outlining a project to use the vehicle "ozonized water", in which the entire cooling process of the rotary instruments is done through this means, this study aimed to evaluate the variation in the concentration of cold drinking water and of injection collected from the triple syringe of the equipment and the triple syringe of the auxiliary unit in relation to the time to establish if it is possible to use potable water for therapeutic purposes, during dental treatments, with lower operational cost. Based on the findings of this preliminary study, applied under conditions of clinical reproducibility, it was established that the data obtained, evaluated by the ANOVA tests, rejected the hypothesis H01, with no significant difference between the concentration of ozonized drinking and injection water collected in the triple syringe (P< 0.05), making it possible to use drinking water for therapeutic purposes, during dental treatments, with lower operating costs. It was also concluded that the concentration of ozonated water decreases as a function of time in the dental chair in all tested groups. In addition, given the average concentrations of ozonized water obtained, it is concluded that its best way of obtaining it is the triple syringe of the auxiliary unit, accepting H02.-
Descrição: dc.descriptionNão recebi financiamento-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsinfo:eu-repo/semantics/restrictedAccess-
Palavras-chave: dc.subjectOxigênio-
Palavras-chave: dc.subjectOzônio-
Palavras-chave: dc.subjectOzonioterapia-
Palavras-chave: dc.subjectOxygen-
Palavras-chave: dc.subjectOzone-
Palavras-chave: dc.subjectOzone therapy-
Título: dc.titleAvaliação da variação da concentração da água ozonizada potável e de injeção coletadas na seringa tríplice do equipo e da unidade auxiliar em relação ao tempo de armazenamento em reservatório de cadeira odontológica-
Título: dc.titleEvaluation of the variation in the concentration of ozonized drinking and injection water collected in the triple syringe of the equipment and the auxiliary unit in relation to the storage time in a dental chair reservoir-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.