Influence of the Near-Cortical Over-Drilling Technique on the Mechanical Behaviour of Locking Plate Constructs Applied in Maned Wolf's Femur

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorFederal University of Viçosa-
Autor(es): dc.contributorSAMT - Structural Solutions for Finite Elements-
Autor(es): dc.contributorMechanical and Metallography Testing Laboratory - LEMM-
Autor(es): dc.contributorUniversity of Marília (UNIMAR)-
Autor(es): dc.creatorSiqueira, Rafael C.-
Autor(es): dc.creatorRahal, Sheila C.-
Autor(es): dc.creatorMesquita, Luciana R.-
Autor(es): dc.creatorVoorwald, Fabiana A.-
Autor(es): dc.creatorFernandes, Martin F.-
Autor(es): dc.creatorTosati, Marcos-
Autor(es): dc.creatorRibeiro, Celso R.-
Autor(es): dc.creatorScorsato, Paulo S.-
Data de aceite: dc.date.accessioned2025-08-21T17:31:00Z-
Data de disponibilização: dc.date.available2025-08-21T17:31:00Z-
Data de envio: dc.date.issued2023-03-01-
Data de envio: dc.date.issued2023-03-01-
Data de envio: dc.date.issued2021-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1055/s-0042-1748859-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/241107-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/241107-
Descrição: dc.descriptionObjective The aim of this study was to evaluate the influence of near-cortical over-drilling holes on the mechanical behaviour of locking plate constructs applied in maned wolf's femur by using mechanical testing and finite element method (FEM). Study Design Seven pairs of adult maned wolves (Chrysocyon brachyurus) femur bones were randomly distributed into four groups. In all groups, a 3.5 mm locking compression plate, designed with 12 combi-holes and one locked, was applied to the lateral surface of the femur. G1 (n = 4) received bicortical locking screws placed in holes 1, 3, 5, 8, 10 and 12. In G2 (n = 5), the plate was applied as used in G1, but the application of the locked screws involved the near-cortical over-drilling technique. In G3 (n = 4), the plate was applied as used in G2, but the size of the near-cortical over-drilling was larger. The combi-holes 6 and 7 were maintained over a 10 mm fracture gap without screws. All constructs were tested for failure in the axial load. The axial load was applied eccentrically to the femoral head. Results Statistical differences were observed in the maximum load with G3 > G1 and G3 > G2, and in the deflection with G2 > G1 and G2 > G3. The FEM showed the lowest total displacement of the bone-plate constructs as well as of the plate in G1 compared with G2 and G3. Conclusion The near-cortical over-drilling technique used in unstable fractures induced in the maned wolf's femur showed by static axial compression test that maximum load and deflection are dependent on drill hole size induced in the near-cortex. Based on FEM, the lowest total displacement of the bone-plate constructs was observed in Group 1.-
Descrição: dc.descriptionDepartment of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science São Paulo State University (UNESP), Rubião Júnior s/n, SP-
Descrição: dc.descriptionDepartment of Veterinary Surgery Federal University of Viçosa, MG-
Descrição: dc.descriptionDepartment of Materials and Technology São Paulo State University (UNESP), Guaratinguetá, São Paulo-
Descrição: dc.descriptionSolution Engineering Manager SAMT - Structural Solutions for Finite Elements-
Descrição: dc.descriptionMechanical and Metallography Testing Laboratory - LEMM, Jaú, SP, Rua Luiz Pengo 150-
Descrição: dc.descriptionDepartment of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science University of Marília (UNIMAR), Marília, SP-
Descrição: dc.descriptionDepartment of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science São Paulo State University (UNESP), Rubião Júnior s/n, SP-
Descrição: dc.descriptionDepartment of Materials and Technology São Paulo State University (UNESP), Guaratinguetá, São Paulo-
Idioma: dc.languageen-
Relação: dc.relationVeterinary and Comparative Orthopaedics and Traumatology-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectcanid-
Palavras-chave: dc.subjectfinite element method-
Palavras-chave: dc.subjectfracture-
Palavras-chave: dc.subjectlocked plate-
Palavras-chave: dc.subjectnear-cortex overdrilling-
Título: dc.titleInfluence of the Near-Cortical Over-Drilling Technique on the Mechanical Behaviour of Locking Plate Constructs Applied in Maned Wolf's Femur-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.