Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Function

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Federal de São Paulo (UNIFESP)-
Autor(es): dc.contributorEscola Paulista de Medicina-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.contributorHospital Israelita Albert Einstein-
Autor(es): dc.contributorHospital Samaritano-
Autor(es): dc.contributorSanta Casa de São Paulo-
Autor(es): dc.contributorHospital Bandeirantes-
Autor(es): dc.contributorHospital do Servidor Público Estadual-
Autor(es): dc.contributorHospital Beneficência Portuguesa-
Autor(es): dc.contributorHospital Dante Pazzanese-
Autor(es): dc.contributorHospital de Base de São José do Rio Preto-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorSanta Casa de Ribeirão Preto-
Autor(es): dc.contributorHospital Alemão Oswaldo Cruz-
Autor(es): dc.contributorHospital Santa Marcelina-
Autor(es): dc.creatorTedesco-Silva, Helio-
Autor(es): dc.creatorOfferni, Juliano Chrystian Mello-
Autor(es): dc.creatorCarneiro, Vanessa Ayres-
Autor(es): dc.creatorPaula, Mayara Ivani de-
Autor(es): dc.creatorDavid Neto, Elias-
Autor(es): dc.creatorLemos, Francine Brambate Carvalhinho-
Autor(es): dc.creatorMoura, Lúcio Roberto Requião-
Autor(es): dc.creatorSilva Filho, Alvaro Pacheco e-
Autor(es): dc.creatorCunha, Mirian de Fátima de Morais-
Autor(es): dc.creatorSilva, Erica Francisco da-
Autor(es): dc.creatorMiorin, Luiz Antonio-
Autor(es): dc.creatorDemetrio, Daniela Priscila-
Autor(es): dc.creatorLuconi, Paulo Sérgio-
Autor(es): dc.creatorLuconi, Waldere Tania da Silva-
Autor(es): dc.creatorBobbio, Savina Adriana-
Autor(es): dc.creatorKuschnaroff, Liz Milstein-
Autor(es): dc.creatorNoronha, Irene Lourdes-
Autor(es): dc.creatorBraga, Sibele Lessa-
Autor(es): dc.creatorBarsante, Renata Cristina-
Autor(es): dc.creatorMoreira, João Cezar Mendes-
Autor(es): dc.creatorFernandes-Charpiot, Ida Maria Maximina-
Autor(es): dc.creatorAbbud-Filho, Mario-
Autor(es): dc.creatorde Andrade, Luis Gustavo Modelli-
Autor(es): dc.creatorGarcia, Paula Dalsoglio-
Autor(es): dc.creatorSaber, Luciana Tanajura Santamaria-
Autor(es): dc.creatorLaurindo, Alan Fernandes-
Autor(es): dc.creatorChocair, Pedro Renato-
Autor(es): dc.creatorNeto, Américo Lourenço Cuvello-
Autor(es): dc.creatorZanocco, Juliana Aparecida-
Autor(es): dc.creatorde Almeida Soares Filho, Antonio Jose Duboc-
Autor(es): dc.creatorAguiar, Wilson Ferreira-
Autor(es): dc.creatorPestana, Jose Medina-
Data de aceite: dc.date.accessioned2025-08-21T22:05:49Z-
Data de disponibilização: dc.date.available2025-08-21T22:05:49Z-
Data de envio: dc.date.issued2023-03-01-
Data de envio: dc.date.issued2023-03-01-
Data de envio: dc.date.issued2017-05-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1097/TXD.0000000000000672-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/240998-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/240998-
Descrição: dc.descriptionBackground. This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). Methods. In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. Results. Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m2 vs 49.0 ± 26.9 mL/min per 1.73 m2; P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m2 vs 54.4 ± 28.6 mL/min per 1.73 m2; P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. Conclusions. In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method.-
Descrição: dc.descriptionHospital do Rim Universidade Federal de São Paulo, SP-
Descrição: dc.descriptionOrganização de Procura de Orgãos Escola Paulista de Medicina, SP-
Descrição: dc.descriptionHospital das Clínicas da Faculdade de Medicina Universidade de São Paulo, SP-
Descrição: dc.descriptionKidney Transplant Unit Hospital Israelita Albert Einstein, SP-
Descrição: dc.descriptionHospital Samaritano, SP-
Descrição: dc.descriptionSanta Casa de São Paulo, SP-
Descrição: dc.descriptionHospital Bandeirantes, SP-
Descrição: dc.descriptionHospital do Servidor Público Estadual, SP-
Descrição: dc.descriptionHospital Beneficência Portuguesa, SP-
Descrição: dc.descriptionHospital Dante Pazzanese, SP-
Descrição: dc.descriptionHospital de Base de São José do Rio Preto, SP-
Descrição: dc.descriptionDepartment of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu-
Descrição: dc.descriptionSanta Casa de Ribeirão Preto, SP-
Descrição: dc.descriptionHospital Alemão Oswaldo Cruz, SP-
Descrição: dc.descriptionHospital Santa Marcelina, SP-
Descrição: dc.descriptionNephrology Division Hospital do Rim Universidade Federal de São Paulo, Rua Borges Lagoa, 960-11 Andar-
Descrição: dc.descriptionDepartment of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu-
Idioma: dc.languageen-
Relação: dc.relationTransplantation Direct-
???dc.source???: dc.sourceScopus-
Título: dc.titleRandomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Function-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.