Efeito do LED violeta na alteração cromática e na variação da temperatura dentinária

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorBriso, André Luiz Fraga-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorClemente, Camila Ferro-
Data de aceite: dc.date.accessioned2025-08-21T19:34:18Z-
Data de disponibilização: dc.date.available2025-08-21T19:34:18Z-
Data de envio: dc.date.issued2022-09-14-
Data de envio: dc.date.issued2022-09-14-
Data de envio: dc.date.issued2022-07-25-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/236562-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/236562-
Descrição: dc.descriptionTem sido demonstrado que o uso de diodos emissores de luz violeta (LEDs) por emitirem luz de comprimento de onda coincidente com o pico de absorção das moléculas cromóforas, possam causar instabilidade e quebrar estes pigmentos, resultando no efeito clareador, sem o uso de peróxido. O objetivo deste estudo foi avaliar in vitro a ação do LED violeta na alteração cromática e na variação da temperatura de discos de dentina pigmentados por diferentes substâncias: GI - dentes naturalmente escurecidos; GII - chá preto; GIII - café; GIV- vinho e GV – sangue. Para tanto, 120 dentes foram selecionados de acordo com a cor inicial, recebendo diferentes protocolos de pigmentação. Após pigmentados, foram novamente selecionados 12 espécimes de cada grupo, de tal forma que houve a padronização da intensidade de pigmentação, todos atingiram o mesmo valor de alteração cromática. Na sequência, foi realizada 1 sessão clareadora e a variação de temperatura foi mensurada simultaneamente, através de um aparelho termopar tipo K. Os dados de alteração cromática (Delta E, a b e L), efeito clareador (WID) e variação da temperatura (Delta T) foram submetidos à Análise de Variância e Teste Tukey ao nível de significância de 5%. Os valores de alteração cromática mais relevantes foram atingidos pelo grupo GIII, assemelhando-se ao grupo controle (GI), respondendo de forma positiva ao tratamento. Em contrapartida, o grupo GV foi o que mais se distanciou do grupo controle, denotando dificuldade de resposta ao tratamento. Com relação ao índice de clareamento ∆WID apenas o grupo GIV apresentou resultados inferiores aos demais. As maiores alterações de temperatura foram observadas no grupo GV. Conclui-se que o LED violeta proporcionou alteração cromática gerando efeito clareador notório, sendo as pigmentações com vinho tinto e sangue as que apresentaram maior dificuldade em responder ao tratamento, além de promover maior elevação da temperatura nos dentes pigmentados com sangue.-
Descrição: dc.descriptionIt has been shown that the use of violet light-emitting diodes (LEDs) by emitting light of a wavelength coinciding with the absorption peak of the chromophore molecules, can cause instability and break these pigments, resulting in the whitening effect, without the use of peroxide. The aim of this study was to evaluate in vitro the action of violet LED on the chromatic alteration and on the temperature variation of dentin discs pigmented by different substances: GI - naturally darkened teeth; GII – black tea; GIII - coffee; GIV- wine and GV - blood. For that, 120 teeth were selected according to the initial color, receiving different pigmentation protocols. After pigmentation, 12 specimens from each group were again selected, in such a way that there was a standardization of pigmentation intensity, all of them reached the same chromatic change value. Subsequently, one bleaching session was performed and the temperature variation was measured simultaneously, using a type K thermocouple device. The chromatic change data (Delta E, a b and L), bleaching effect (WID) and temperature variation (Delta T) were submitted to Analysis of Variance and Tukey Test at a significance level of 5%. The most relevant chromatic alteration values were reached by the GIII group, similar to the control group (GI), responding positively to the treatment. On the other hand, the GV group was the one that most distanced itself from the control group, showing difficulty in responding to treatment. Regarding the whitening index ΔWID, only the GIV group presented lower results than the others. The greatest temperature changes were observed in the GV group. It was concluded that the violet LED provided a chromatic change, generating a noticeable whitening effect, and the pigmentations with red wine and blood were the ones that presented greater difficulty in responding to the treatment, in addition to promoting a greater temperature rise in the teeth pigmented with blood.-
Descrição: dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
Descrição: dc.descriptionFAPESP: 2020/10021-9-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsinfo:eu-repo/semantics/openAccess-
Palavras-chave: dc.subjectClareamento dental-
Palavras-chave: dc.subjectDentina-
Palavras-chave: dc.subjectCor-
Palavras-chave: dc.subjectTooth bleaching-
Título: dc.titleEfeito do LED violeta na alteração cromática e na variação da temperatura dentinária-
Título: dc.titleEffect of violet LED on chromatic change and dentin temperature variation-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.