Caracterização e aplicações da instrumentação usada no controle de qualidade de feixes de radiodiagnóstico e radioterapia

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFernandes, Marco Antônio Rodrigues-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorHungaro, Thales Hilario-
Data de aceite: dc.date.accessioned2025-08-21T16:10:53Z-
Data de disponibilização: dc.date.available2025-08-21T16:10:53Z-
Data de envio: dc.date.issued2022-06-24-
Data de envio: dc.date.issued2022-06-24-
Data de envio: dc.date.issued2019-06-12-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/235319-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/235319-
Descrição: dc.descriptionuso de radiações ionizantes tem apresentado um crescimento constante e acentuado nas diversas atividades, principalmente na área da medicina, o que induz no aumento do acometimento de reações adversas devido à interação da radiação com o tecido biológico. Os preceitos da proteção radiológica apontam para a necessidade do uso de técnicas de medidas de radiação que permitam o pleno conhecimento do comportamento dos diferentes tipos de feixes de radiação quando da sua interação com tecido biológico. Nas faixas de energias de radiações usadas nos segmentos do radiodiagnóstico e adioterapia, os detectores do tipo câmaras de ionização apresentam melhor linearidade na relação dose-resposta. Neste trabalho, foram avaliados os comportamentos de diferentes tipos de câmaras de ionização quando submetidas à diferentes tipos de feixes e energias de radiação. Os resultados corroboram com as recomendações da literatura no que se refere à importância da calibração e do uso adequado dos instrumentos detectores de radiações ionizantes, para as respectivas faixas de energias de aplicação.-
Descrição: dc.descriptionThe use of ionizing radiation has shown a constant and marked increase in the various activities, mainly in the medical field, which induces in the increase of adverse reactions due to the interaction of radiation and biological tissue. The precepts of radiation protection point to the need of using techniques in radiation measurements that allow the full knowledge of the behavior of different types of radiation beams when interacting with biological tissue. In the ranges of radiation energies used in radiodiagnosis and radiotherapy, ionization chamber type detectors have a better linearity in the dose-response relationship. In the present study, the behavior of different types of ionization chambers was evaluated when submitted to different types of beams and radiation energies. The results corroborate with the recommendations of the literature regarding the importance of the calibration of ionizing radiation detector instruments for the respective ranges of application energies and it’s correct choose.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsinfo:eu-repo/semantics/openAccess-
Palavras-chave: dc.subjectCâmaras de Ionização-
Palavras-chave: dc.subjectControle de Qualidade-
Palavras-chave: dc.subjectDosimetria-
Palavras-chave: dc.subjectRaio X-
Palavras-chave: dc.subjectQuality Control-
Palavras-chave: dc.subjectIon Chambers-
Palavras-chave: dc.subjectDosimetry-
Palavras-chave: dc.subjectX rays-
Título: dc.titleCaracterização e aplicações da instrumentação usada no controle de qualidade de feixes de radiodiagnóstico e radioterapia-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.