Passivation Level of AISI 316L Aseptic Tank Surface Quantified by On-Site Electrochemical Techniques

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSoudap Soldas Sanitárias-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorCorrosion & Protection Centre-
Autor(es): dc.creatorGuilhermea, Luis Henrique-
Autor(es): dc.creatorBenedetti, Assis Vicente-
Autor(es): dc.creatorFugivara, Cecílio Sadao-
Autor(es): dc.creatorEngelberg, Dirk-
Data de aceite: dc.date.accessioned2025-08-21T18:56:29Z-
Data de disponibilização: dc.date.available2025-08-21T18:56:29Z-
Data de envio: dc.date.issued2022-05-01-
Data de envio: dc.date.issued2022-05-01-
Data de envio: dc.date.issued2021-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/1980-5373-MR-2021-0623-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/234238-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/234238-
Descrição: dc.descriptionFrequently stainless steel AISI 316L aseptic tanks have their passivity and corrosion resistance properties degraded by biofilm formation and localized corrosion processes. Thereby, maintenance projects are performed to repair the surface in food-grade product contact to obtain an aseptic property as defined by ASME BPE. However, the on-site non-destructive testing are limited to the liquid penetrant examination and the average roughness measurement. The on-site open circuit potential and on-site cyclic polarization measurements were conducted using a portable electrochemical minicell. The level of passivation was quantified on the tank surface, and it was performed before and after the repairing maintenance protocol be made. The results of the on-site electrochemical measurements showed a clear difference between as-degraded and repaired surfaces, indicating a sensible response to aseptic surface inspection. The on-site open circuit potential together with the on-site cyclic polarization were considered an advanced tool to support the maintenance projects of the AISI 316L aseptic surfaces.-
Descrição: dc.descriptionSoudap Soldas Sanitárias, SP-
Descrição: dc.descriptionUniversidade Estadual Paulista Instituto de quimica, SP-
Descrição: dc.descriptionThe University of Manchester Department of Materials Corrosion & Protection Centre-
Descrição: dc.descriptionUniversidade Estadual Paulista Instituto de quimica, SP-
Idioma: dc.languageen-
Relação: dc.relationMaterials Research-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subject316L stainless steel-
Palavras-chave: dc.subjectAseptic tank-
Palavras-chave: dc.subjectASME BPE-
Palavras-chave: dc.subjectCorrosion monitoring-
Palavras-chave: dc.subjectLocalized corrosion-
Palavras-chave: dc.subjectOn-site cyclic polarization-
Título: dc.titlePassivation Level of AISI 316L Aseptic Tank Surface Quantified by On-Site Electrochemical Techniques-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp