Influence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorBorges, Alexandre Luiz Souto-
Autor(es): dc.creatorDe Lima, Aline Lins-
Autor(es): dc.creatorCampaner, Larissa Mendes-
Autor(es): dc.creatorBottino, Marco Antonio-
Autor(es): dc.creatorDe Oliveira Dal Piva, Amanda Maria-
Autor(es): dc.creatorTribst, João Paulo Mendes-
Data de aceite: dc.date.accessioned2025-08-21T17:47:11Z-
Data de disponibilização: dc.date.available2025-08-21T17:47:11Z-
Data de envio: dc.date.issued2022-05-01-
Data de envio: dc.date.issued2022-05-01-
Data de envio: dc.date.issued2021-05-11-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.5195/D3000.2021.118-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/233145-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/233145-
Descrição: dc.descriptionObjectives: This study compared the influence of occlusal anatomy on acrylic CAD/CAM crowns fracture load and stress distribution. The null hypothesis was that there would be no difference between the provisional crowns fracture load and stress according to different occlusal anatomy. Methods: A full-crown preparation was simulated using dentin analogue (G10, Protec, São Paulo, Brazil) totaling 20 identical preparations. Next, twenty acrylic crowns were milled using different occlusal design parameter (Young or Adult) available in the software database. The crowns were cemented (Temp-bond, NE Kerr Dental, Brea, CA, USA) and fractured using a compressive load (0.5 mm/min of cross-head speed). Data were analyzed by using one-way ANOVA and Tukey tests (p< 0.05). A similar geometry was modeled and exported to the analysis software to perform a static structural analysis. The maximum principal stress was calculated using the finite element method with 300 N chewing load simulation. Results: The occlusal anatomy significantly influenced the load-to-fracture (p<0.05). Young design showed lower fracture load (1139±132 N) than Adult design (2007±345 N). The tensile stress distribution showed a similar pattern for both groups however the highest stress peak was calculated for Young design (76 MPa) in the occlusal surface. Conclusion: The anatomy design with higher cusp angulation and occlusal sulcus more evident can increase the stress concentration and reduce the fracture load for acrylic resin CAD/CAM crowns.-
Descrição: dc.descriptionDepartment of Dental Material and Prosthodontics São Paulo State University Institute of Science and Technology-
Descrição: dc.descriptionDepartment of Dental Material and Prosthodontics São Paulo State University Institute of Science and Technology-
Idioma: dc.languageen-
Relação: dc.relationDentistry 3000-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectAcrylic Resins-
Palavras-chave: dc.subjectComputer-Aided Design-
Palavras-chave: dc.subjectCrowns-
Palavras-chave: dc.subjectFinite Element Analysis-
Palavras-chave: dc.subjectWeight-Bearing-
Título: dc.titleInfluence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.