Effect of light-curing methods on resin cement knoop hardness at different depths

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.creatorSinhoreti, Mário Alexandre Coelho-
Autor(es): dc.creatorManetta, Izabella Paola-
Autor(es): dc.creatorTango, Rubens Nisie-
Autor(es): dc.creatorIriyama, Nelson Tetsu-
Autor(es): dc.creatorConsani, Rafael Leonardo Xediek-
Autor(es): dc.creatorCorrer-Sobrinho, Lourenço-
Data de aceite: dc.date.accessioned2025-08-21T17:42:32Z-
Data de disponibilização: dc.date.available2025-08-21T17:42:32Z-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2007-01-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/S0103-64402007000400006-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/231196-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/231196-
Descrição: dc.descriptionThis study evaluated, using Knoop hardness test, the polymerization depth of Rely-X dual-cured resin cement activated by chemical reaction alone (control group) or by chemical/physical mode with light curing through a 1.5-mm-thick ceramic layer (HeraCeram). Bovine incisors had their buccal surface flattened and hybridized. On this surface, a rubber mould (5 mm diameter; 1 mm high) was bulk filled with cement. Either a polyester strip or a 1.5-mm-thick disc of the veneering material was seated over this set. Light curing was performed with either conventional halogen light (QTH; XL2500) for 40 s, light-emitting diode (LED; Ultrablue Is) for 40 s or xenon plasma arc (PAC; Apollo 95E) for 3 s. In a control group, cement setting occurred by chemical reaction alone. After storage dry in dark (24 h/37oC), the specimens (n=5) were sectioned for hardness (KHN) measurements at three depths in a microhardness tester (50 gf load/15 s). Data were submitted to ANOVA and Tukey's test (α = 0.05). Rely-X cement presented higher Knoop hardness values when the QTH and LED LCUs were used, compared to the control group and PAC. Light curing with PAC resulted in lower hardness compared to the control group. Cement hardness was significantly lower in deeper regions.-
Descrição: dc.descriptionDental Materials Area Department of Restorative Dentistry School of Dentistry of iracicaba State University of Campinas, Piracicaba, SP-
Descrição: dc.descriptionDental Materials Area Department of Dental Materials and Prosthodontics School of Dentistry of São Jose dos Campos State University of São Paulo, São Jose dos Campos, SP-
Descrição: dc.descriptionProsthodontics Area Department of Prosthodontics and Periodontics School of Dentistry of Piracicaba State University of Campinas, Piracicaba-
Formato: dc.format305-308-
Idioma: dc.languageen-
Relação: dc.relationBrazilian Dental Journal-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDental porcelain-
Palavras-chave: dc.subjectHardness-
Palavras-chave: dc.subjectPolymerization-
Palavras-chave: dc.subjectResin cement-
Título: dc.titleEffect of light-curing methods on resin cement knoop hardness at different depths-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.