CeO2 nanostructured electrochemical sensor for the simultaneous recognition of diethylstilbestrol and 17β-estradiol hormones

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual de Mato Grosso do Sul (UEMS)-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorSouza, Matheus B.-
Autor(es): dc.creatorSantos, Jaqueline S.-
Autor(es): dc.creatorPontes, Montcharles S.-
Autor(es): dc.creatorNunes, Letícia R.-
Autor(es): dc.creatorOliveira, Ivan P.-
Autor(es): dc.creatorLopez Ayme, Alvaro J.-
Autor(es): dc.creatorSantiago, Etenaldo F.-
Autor(es): dc.creatorGrillo, Renato-
Autor(es): dc.creatorFiorucci, Antonio R.-
Autor(es): dc.creatorArruda, Gilberto J.-
Data de aceite: dc.date.accessioned2025-08-21T17:48:36Z-
Data de disponibilização: dc.date.available2025-08-21T17:48:36Z-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2022-01-19-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1016/j.scitotenv.2021.150348-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/229544-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/229544-
Descrição: dc.descriptionA new highly sensitive, selective, and inexpensive electrochemical method has been developed for simultaneously detecting diethylstilbestrol (DES) and 17β-estradiol (E2) in environmental samples (groundwater and lake water) using a graphite sensor modified by cerium oxide nanoparticles (CPE-CeO2 NPs). The developed sensor and the materials used in its preparation were characterized using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The ab initio simulation was used to evaluate the adsorption energies between both DES and E2 with the surface of the sensor. The peak current of oxidation of both hormones showed two regions of linearity. The region of greatest sensitivity was observed for the linear range of 10 nM–100 nM. The detection and quantification limits for this concentration range were 0.8/2.6 nM and 1.3/4.3 nM for DES and E2, respectively. The analytical performance of the developed method showed high sensitivity, precision, repeatability, reproducibility, and selectivity. The CPE-CeO2 NPs sensor was successfully applied to simultaneously detect DES and E2 in real samples with recovery levels above 98%.-
Descrição: dc.descriptionPrograma de Pós-Graduação em Recursos Naturais Universidade Estadual de Mato Grosso do Sul (UEMS), P.O. Box 351-
Descrição: dc.descriptionInstituto de Ciências Biomédicas Universidade de São Paulo (USP), Av. Prof. Lineu Prestes, 1374, Butantã-
Descrição: dc.descriptionInstituto de Química Universidade Estadual de Campinas (UNICAMP), Rua Josué de Castro, s/n, Cidade Universitária-
Descrição: dc.descriptionDepartamento de Física e Química Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista (UNESP), Avenida Brasil, 56, Centro-
Descrição: dc.descriptionDepartamento de Física e Química Faculdade de Engenharia de Ilha Solteira Universidade Estadual Paulista (UNESP), Avenida Brasil, 56, Centro-
Idioma: dc.languageen-
Relação: dc.relationScience of the Total Environment-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectAdsorption-
Palavras-chave: dc.subjectCeO2 nanoparticles-
Palavras-chave: dc.subjectEstrogens-
Palavras-chave: dc.subjectReal samples-
Palavras-chave: dc.subjectVoltammetry-
Título: dc.titleCeO2 nanostructured electrochemical sensor for the simultaneous recognition of diethylstilbestrol and 17β-estradiol hormones-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.