Torque stability of different abutment screws submitted to mechanical cycling

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.creatorVianna, Camila de Assis-
Autor(es): dc.creatorAparecida Delben, Juliana-
Autor(es): dc.creatorBarão, Valentim A.R.-
Autor(es): dc.creatorBarbosa Ferreira, Mayara-
Autor(es): dc.creatorHenrique dos Santos, Paulo-
Autor(es): dc.creatorGonçalves Assunçao, Wirley-
Data de aceite: dc.date.accessioned2025-08-21T15:34:11Z-
Data de disponibilização: dc.date.available2025-08-21T15:34:11Z-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2013-01-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.11607/jomi.3110-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/227715-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/227715-
Descrição: dc.descriptionPurpose: To evaluate the torque stability of different UCLA retention screws of single implant-supported crowns submitted to mechanical cycling. Materials and Methods: Crowns fabricated from nickel-chromiummolybdenum alloy were attached to external-hexagon implants and grouped by the different retention screws used (n = 10): Ti, titanium screws (BRUNIHT, Biomet 3i); Au, gold-palladium screws with 24-carat gold coating (Gold-Tite, Biomet 3i); TiC, titanium alloy (Ti-6Al-4V) screw with diamondlike carbon coating (Neotorque, Neodent); and TiN, Ti-6Al-4V screw with aluminum-titanium-nitride coating (Ti-Tite, Conexão). Three initial removal torque (RT) values were obtained for each screw after torque insertion using an analog torque gauge. The final RT was measured after mechanical cycling (1 × 106 cycles at 2 Hz under 130 N). Data were submitted to analysis of variance and the Fischer test. Results: Statistically significant differences were observed between the initial RT in groups Ti and TiN, and between TiC and TiN. No statistically significant difference was seen between mean RT obtained before and after mechanical cycling, except for the Ti screws. All groups exhibited similar torque maintenance after mechanical cycling. Conclusion: Although no significant difference was observed among groups for the final percentage of torque maintenance, the final RT values of the coated screws were higher than those of the noncoated screws. © 2013 by Quintessence Publishing Co Inc.-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Aracatuba Dental School Univ Estadual Paulista (UNESP), Aracatuba, SP-
Descrição: dc.descriptionDepartment of Prosthodontics and Periodontology Piracicaba Dental School University of Campinas (UNICAMP), Piracicaba, SP-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Aracatuba Dental School Univ Estadual Paulista (UNESP), Aracatuba, SP-
Formato: dc.formate209-e214-
Idioma: dc.languageen-
Relação: dc.relationInternational Journal of Oral and Maxillofacial Implants-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectCoating-
Palavras-chave: dc.subjectGold-
Palavras-chave: dc.subjectImplant-supported prosthesis-
Palavras-chave: dc.subjectRetention screw-
Palavras-chave: dc.subjectTitanium-
Palavras-chave: dc.subjectTorque maintenance-
Título: dc.titleTorque stability of different abutment screws submitted to mechanical cycling-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.