Analysis of electric characteristics of high-elevation stretches of the tucuruí-macapá-manaus connection

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.creatorKurokawa, Sérgio-
Autor(es): dc.creatorCosta, Eduardo C. M.-
Autor(es): dc.creatorPinto, André J. G.-
Autor(es): dc.creatorFilho, José Pissolato-
Data de aceite: dc.date.accessioned2025-08-21T18:36:04Z-
Data de disponibilização: dc.date.available2025-08-21T18:36:04Z-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2022-04-29-
Data de envio: dc.date.issued2013-10-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1007/s40313-013-0059-5-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/227449-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/227449-
Descrição: dc.descriptionThis article contains a detailed study of the parameters and electric characteristics of a transmission system proposed to electrically connect the cities ofTucuruí,Macapá and Manaus. Several sections of this transmission line will be supported by steel towers 280 m high to suspend the line above the Amazon tropical forest. The height of the line and the presence of two dielectrics in the system-the air and the forest-produce unique line parameters compared to the longitudinal parameters of a conventional line, which is approximately 40 m high. A preliminary analysis of the parameters of a line section of the Tucuruí-Macapá-Manaus connection is conducted in this article. The behaviors of potential surges in the line resulting from switching operations and atmospheric discharges are also investigated. © Brazilian Society for Automatics-SBA 2013.-
Descrição: dc.descriptionDepartment of Electrical Engineering School of Engineering of Ilha Solteira UNESP, Ilha Solteira, SP CEP 15385-000-
Descrição: dc.descriptionHigh Voltage Laboratory School of Electrical and Computer Engineering UNICAMP, Campinas, SP CEP 13081-970-
Descrição: dc.descriptionDepartment of Electrical Engineering School of Engineering of Ilha Solteira UNESP, Ilha Solteira, SP CEP 15385-000-
Formato: dc.format714-724-
Idioma: dc.languageen-
Relação: dc.relationJournal of Control, Automation and Electrical Systems-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectElectromagnetic transients-
Palavras-chave: dc.subjectTransmission line-
Palavras-chave: dc.subjectTucuruí-Macapá-Manaus connection-
Título: dc.titleAnalysis of electric characteristics of high-elevation stretches of the tucuruí-macapá-manaus connection-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp