Influence of microwave sterilization on the cutting capacity of carbide burs

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorFais, Laiza Maria Grassi-
Autor(es): dc.creatorPinelli, Lígia Antunes Pereira-
Autor(es): dc.creatorAdabo, Gelson Luis-
Autor(es): dc.creatorda Silva, Regina Helena Barbosa Tavares-
Autor(es): dc.creatorMarcelo, Caroline Canhizares-
Autor(es): dc.creatorGuaglianoni, Dalton Geraldo-
Data de aceite: dc.date.accessioned2025-08-21T16:04:49Z-
Data de disponibilização: dc.date.available2025-08-21T16:04:49Z-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2009-01-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/S1678-77572009000600009-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/225704-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/225704-
Descrição: dc.descriptionObjective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, SP-
Descrição: dc.descriptionDepartment of Mathematics and Statistics School of Science and Letters São Paulo State University, Araraquara, SP-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, SP-
Descrição: dc.descriptionDepartment of Mathematics and Statistics School of Science and Letters São Paulo State University, Araraquara, SP-
Formato: dc.format584-589-
Idioma: dc.languageen-
Relação: dc.relationJournal of Applied Oral Science-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDental instruments-
Palavras-chave: dc.subjectInfection control-
Palavras-chave: dc.subjectMicrowaves-
Palavras-chave: dc.subjectSterilization-
Título: dc.titleInfluence of microwave sterilization on the cutting capacity of carbide burs-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.