Modal transformation applied to double three-phase transmission lines

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.contributorFederal University of Rio de Janeiro-
Autor(es): dc.creatorDo Prado, Afonso José-
Autor(es): dc.creatorKurokawa, Sérgio-
Autor(es): dc.creatorFilho, José Pissolato-
Autor(es): dc.creatorBovolato, Luiz Fernando-
Autor(es): dc.creatorTavares, Maria Cristina D.-
Autor(es): dc.creatorPortela, Carlos Maunel-
Data de aceite: dc.date.accessioned2025-08-21T23:26:34Z-
Data de disponibilização: dc.date.available2025-08-21T23:26:34Z-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2004-12-01-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/224576-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/224576-
Descrição: dc.descriptionDouble three-phase transmission lines are analyzed in this paper using a modal transformation model. The main attribute of this model is the use of a single real transformation matrix based on line geometrical characteristics and the Clarke matrix. Because of this, for any line point, the electrical values can be accessed for phase domain or mode domain using the considered transformation matrix and without convolution methods. For non-transposed symmetrical lines the errors between the model results and the exact modes are insignificant values. The eigenvector and eigenvalue analyses for transposed lines search the similarities among the three analyzed transposition types and the possible simplifications for a non-transposed case. © 2004 IEEE.-
Descrição: dc.descriptionElectrical Engineering Department FEIS/UNESP University of São Paulo State-
Descrição: dc.descriptionElectrical Engineering Department DSCE/FEEC/UNICAM Campinas University State-
Descrição: dc.descriptionFederal University of Rio de Janeiro-
Descrição: dc.descriptionElectrical Engineering Department FEIS/UNESP University of São Paulo State-
Formato: dc.format308-313-
Idioma: dc.languageen-
Relação: dc.relation2004 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectClarke matrix-
Palavras-chave: dc.subjectEigenvalue-
Palavras-chave: dc.subjectEigenvector-
Palavras-chave: dc.subjectFrequency-
Palavras-chave: dc.subjectMode domain-
Palavras-chave: dc.subjectTransformation matrix-
Palavras-chave: dc.subjectTransmission lines-
Título: dc.titleModal transformation applied to double three-phase transmission lines-
Tipo de arquivo: dc.typeaula digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.