Mass Transfer Performance of Ethanol Removal by CO2 Stripping in Different Pneumatic Bioreactors

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Federal de São Carlos (UFSCar)-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.creatorMartins, Taise B.-
Autor(es): dc.creatorAlmeida, Letícia P.-
Autor(es): dc.creatorCerri, Marcel O.-
Autor(es): dc.creatorBadino, Alberto C.-
Data de aceite: dc.date.accessioned2022-08-04T22:08:38Z-
Data de disponibilização: dc.date.available2022-08-04T22:08:38Z-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2020-04-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1089/ind.2019.0035-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/221469-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/221469-
Descrição: dc.descriptionThe hydrodynamics and mass transfer characteristics of ethanol stripping with CO2 were evaluated for a 2.0-L pneumatic bioreactor operated in bubble column (BC), concentric-tube airlift (CTA), and split-cylinder airlift (SCA) configurations, as well as for bubble columns with three different working volumes (2.0, 5.0, and 10.0 L). The results showed that an increase of the global gas hold-up (G) did not enhance ethanol removal in any of these prototypes. The volumetric ethanol removal coefficient (kLEa) values were very similar for the three models, despite the higher G obtained for the CTA configuration. The same behavior was observed for the three scales of BC prototypes, except for distinct behavior observed at the 10.0-L scale operated above 2.5 vvm. In order to predict kLEa for different scales and operational conditions, a dimensionless correlation was proposed for the Sherwood number, which provided an excellent fit to the experimental data, with few points exceeding ±10% deviation. The ethanol concentration factor (FC) values increased with decrease of the specific gas flow rates, with the highest FC value of around 6.0 (6 times the original solution concentration) obtained for the 10.0-L scale of BC. Therefore, increasing the prototype size led to an increase of Fc, resulting in greater ethanol enrichment of the gas stream leaving the equipment.-
Descrição: dc.descriptionGraduate Program of Chemical Engineering Federal University of São Carlos, C.P. 676-
Descrição: dc.descriptionDepartment of Bioprocesses and Biotechnology Faculty of Pharmaceutical Sciences, University of São Paulo State-
Formato: dc.format81-90-
Idioma: dc.languageen-
Relação: dc.relationIndustrial Biotechnology-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectCO2 stripping-
Palavras-chave: dc.subjectextractive ethanol fermentation-
Palavras-chave: dc.subjecthydrodynamics-
Palavras-chave: dc.subjectmass transfer-
Palavras-chave: dc.subjectpneumatic bioreactor-
Título: dc.titleMass Transfer Performance of Ethanol Removal by CO2 Stripping in Different Pneumatic Bioreactors-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.