The influence of the structure area on the performance of SHM systems based on E/M impedance

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorBaptista, F. [UNESP]-
Autor(es): dc.creatorFilho, J. V. [UNESP]-
Data de aceite: dc.date.accessioned2022-08-04T22:05:02Z-
Data de disponibilização: dc.date.available2022-08-04T22:05:02Z-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2009-01-01-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/220476-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/220476-
Descrição: dc.descriptionPiezoelectric transducers of PZT (lead zirconate titanate) have been widely used in structural health monitoring (SHM) systems based on the electromechanical (E/M) impedance technique and many studies indicate the efficiency of PZT to detect structural damages. However, some practical considerations still have to be considered in real applications. In this work, the goal was to evaluate the effect of the cross-section area of the monitored structure. Tests show that SHM based on E/M impedance is less efficient when the monitored structure has large cross-section area.-
Descrição: dc.descriptionDepartment of Electrical Engineering São Paulo State University - UNESP-
Descrição: dc.descriptionDepartment of Electrical Engineering São Paulo State University - UNESP-
Formato: dc.format691-697-
Idioma: dc.languageen-
Relação: dc.relationStructural Health Monitoring 2009: From System Integration to Autonomous Systems - Proceedings of the 7th International Workshop on Structural Health Monitoring, IWSHM 2009-
???dc.source???: dc.sourceScopus-
Título: dc.titleThe influence of the structure area on the performance of SHM systems based on E/M impedance-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.