Assessment of the interface between implant and abutments of five systems by Scanning Electronic Microscopy

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorOral and Maxillofacial Surgery-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.creatorFujiwara, Carlos Alberto [UNESP]-
Autor(es): dc.creatorFilho, Osvaldo Magro-
Autor(es): dc.creatorOliveira, Nilson T. C. [UNESP]-
Autor(es): dc.creatorQueiroz, Thallita Pereira-
Autor(es): dc.creatorAbla, Marcelo Sabagg [UNESP]-
Autor(es): dc.creatorPardini, Luiz Carlos-
Data de aceite: dc.date.accessioned2022-08-04T22:03:14Z-
Data de disponibilização: dc.date.available2022-08-04T22:03:14Z-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2022-04-28-
Data de envio: dc.date.issued2009-08-01-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/219889-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/219889-
Descrição: dc.descriptionAim: The objective of this study was to assess, by Scanning Electronic Microscopy (SEM), the interface between the platforms of five implant systems and the conic abutments (I) gold ucla type (II) and multi-unit type (III). Materials and methods: The implant systems used and their respective abutments studied were: AS Technology Titanium Fix (I, II, III), Conexão (I, II, III), Neodent (I, II, III), Sterngold Implamed (I, II) and 3i Implant Innovation (I, II). The abutments were screwed to the implants with a 20 Ncm torque. For each sample, 6 points were selected for measurement, 3 on the right and 3 three on the left side: the most external point, the middle point and the most internal point at the interface formed between the implant platform and the abutment. Results: On the outer point there was a variation in measurement from 0 to 11.173 μm, on the middle point there was variation from 0 to 8.314 μm and in the internal point there was a variation from 0 to 15.267 μm. The smallest gaps for abutments I, II and III were obtained with Neodent (0.733 μm), Sterngold Implamed (0.513 μm) and Conexão (0.503 μm), respectively. The Neodent system showed statistically significant differences with the other systems analyzed in the right internal point (p<0.05), while on the left ones differences were not significant only with the the Conexão system (p=0.168); the latter showed statistically significant differences with the other systems except for the 3i system (p=0.311). Conclusion: It is concluded that the Neodent system differed from the other ones in the right and left internal points (p<0.05) except for the Conexão system (p=0.168), which also differed from the other ones, and the 3i system (p=0.311). Maladjustment values obtained are similar to those reported in the literature.-
Descrição: dc.descriptionSão Paulo University State Dental School of Araçatuba UNESP, São Paulo-
Descrição: dc.descriptionOral and Maxillofacial Surgery-
Descrição: dc.descriptionDepartment of Morphology, Dentistry and Physiology Dental School of Ribeirão Preto University of São Paulo, USP-
Descrição: dc.descriptionBiomaterials Group Unesp-Araraquara-
Descrição: dc.descriptionSão Paulo University State Dental School of Araçatuba UNESP, São Paulo-
Descrição: dc.descriptionBiomaterials Group Unesp-Araraquara-
Formato: dc.format60-66-
Idioma: dc.languageen-
Relação: dc.relationJournal of Osseointegration-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectAbutment-
Palavras-chave: dc.subjectGap-
Palavras-chave: dc.subjectImplant-
Palavras-chave: dc.subjectPeri-implant-
Título: dc.titleAssessment of the interface between implant and abutments of five systems by Scanning Electronic Microscopy-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.