Efeito de sucessivas sessões de clareamento caseiro na susceptibilidade ao manchamento e a variações de translucidez e brancura e na topografia de materiais monolíticos CAD/CAM

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFonseca, Renata Garcia [UNESP]-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorCárdenas Ramos, Alejandro-
Data de aceite: dc.date.accessioned2022-08-04T21:56:41Z-
Data de disponibilização: dc.date.available2022-08-04T21:56:41Z-
Data de envio: dc.date.issued2022-04-20-
Data de envio: dc.date.issued2022-04-20-
Data de envio: dc.date.issued2022-02-25-
Data de envio: dc.date.issued2021-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/217970-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/217970-
Descrição: dc.descriptionO efeito de sucessivas sessões de clareamento caseiro nas propriedades ópticas de materiais monolíticos CAD/CAM requer investigação para saber se este procedimento é seguro quanto a essas propriedades. O objetivo deste estudo foi avaliar o efeito da simulação de 1 Procedimento clareador caseiro ao ano, por até 3 anos, na susceptibilidade ao manchamento (ΔE00) e a variações de translucidez (ΔTP00) e brancura (ΔWID) e na topografia de materiais monolíticos CAD/CAM. Discos (10,0 mm x 0,7 mm) de Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP) e IPS e.max CAD (EMAX) foram alocados como segue: 1) não clareados ou 2) clareados com peróxido de carbamida a 10%. Cada procedimento clareador anual constituiu-se na aplicação do gel clareador (Opalescence PF) por 10 h ao dia por 14 dias. Após a mensuração inicial (M0) das coordenadas CIE L*a*b* em espectrofotômetro, os espécimes foram clareados ou não e, então, imersos por um período simulado de 1 ano de exposição ao café antes da próxima mensuração (M1). Este processo (clareamento ou não => manchamento => mensuração) foi repetido mais duas vezes, resultando em M2 e M3. Os valores de ΔE00, ΔTP00 e ΔWID entre M1, M2 e M3 em relação à M0 foram calculados. A topografia foi analisada por microscopia eletrônica de varredura em cada uma das quatro etapas. Os dados foram analisados por ANOVA de Medidas Repetidas Mista e pós-teste de Bonferroni (α=0,05). Em geral, o clareamento aumentou a susceptibilidade ao manchamento de todos os materiais quando comparado aos respectivos grupos não clareados. Ao longo dos anos, o LU, VE e EMAX tiveram a susceptibilidade ao manchamento aumentada pelo clareamento. O clareamento diminuiu a translucidez do VE quando comparado aos grupos não clareados e ao longo dos anos. Quando comparado aos grupos não clareados, em geral, o clareamento favoreceu o manchamento do LU e EMAX e aumentou a brancura do EMP, enquanto o VE não foi afetado. No LU, a brancura diminuiu ao longo dos anos em ambos os tratamentos, enquanto a brancura dos demais materiais não foi afetada com o tempo. Todos os materiais apresentaram alterações topográficas progressivas com o aumento do número de sessões. Sucessivas sessões de clareamento caseiro com peróxido de carbamida a 10% afetaram adversamente a topografia e as propriedades ópticas dos materiais avaliados.-
Descrição: dc.descriptionThe effect of successive at-home bleaching sessions on the optical properties of CAD/CAM monolithic materials requires investigation to determine whether or not this procedure is safe with respect to these properties. The aim of this study was to evaluate the effect of simulating 1 session of at-home bleaching per year, for up to 3 years, on the susceptibility to staining (ΔE00), translucency (ΔTP00) and whiteness (ΔWID) variations, and topography of CAD/CAM monolithic materials. Discs (10.0 mm x 0.7 mm) from Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP) and IPS e.max CAD (EMAX) were allocated as follows: 1) non-bleached or 2) bleached with 10% carbamide peroxide. Each annual bleaching session consisted of applying the whitening gel (Opalescence PF) for 10 hours a day for 14 days. After the initial measurement (M0) of the CIE L*a*b* coordinates by using a spectrophotometer, specimens were bleached or not and then immersed for a simulated period of 1 year of exposure to coffee before the next measurement (M1). This process (bleaching or not => staining => reading) was repeated two more times, resulting in M2 and M3. The ΔE00, ΔTP00 and ΔWID values between M1, M2 and M3 in relation to M0 were calculated. Topography was analyzed by scanning electron microscopy in each of the four steps. Data were analyzed by Mixed Repeated Measures ANOVA and Bonferroni test (α=0.05). In general, bleaching increased the staining susceptibility of all materials when compared to the non-bleached groups and that of the LU, VE and EMAX over the years. Bleaching decreased the translucency of the VE in all years and over the years. When compared to the non-bleached groups, bleaching decreased the whiteness of the LU and EMAX and increased the whiteness of the EMP, while the VE was not affected. In the LU, the whiteness decreased over the years in both treatments, while the other materials were not affected with time. All materials showed progressive topographic changes with the increase in the number of sessions. Successive sessions of at-home bleaching with 10% carbamide peroxide adversely affected the topography and optical properties of the evaluated materials-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
Descrição: dc.descriptionCAPES: 001-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (Unesp)-
Direitos: dc.rightsAcesso restrito-
Direitos: dc.rightsLOCKSS system has permission to collect, preserve, and serve this Archival Unit-
Palavras-chave: dc.subjectDesenho assistido por computador-
Palavras-chave: dc.subjectClareadores-
Palavras-chave: dc.subjectCor-
Palavras-chave: dc.subjectTopografia.-
Palavras-chave: dc.subjectComputer-aided design-
Palavras-chave: dc.subjectBleaching agents-
Palavras-chave: dc.subjectColor-
Palavras-chave: dc.subjectTopography-
Título: dc.titleEfeito de sucessivas sessões de clareamento caseiro na susceptibilidade ao manchamento e a variações de translucidez e brancura e na topografia de materiais monolíticos CAD/CAM-
Título: dc.titleEffect of simulated annual at-home bleaching on susceptibility to staining, translucency and whiteness variations of CAD-CAM monolithic materials-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.