Alteração volumétrica do cimento reparador Bio-C Repair em diferentes condições de pH

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorTanomaru-Filho, Mario [UNESP]-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorSilva, Luana Raphael da-
Data de aceite: dc.date.accessioned2022-08-04T21:56:37Z-
Data de disponibilização: dc.date.available2022-08-04T21:56:37Z-
Data de envio: dc.date.issued2022-04-20-
Data de envio: dc.date.issued2022-04-20-
Data de envio: dc.date.issued2022-03-24-
Data de envio: dc.date.issued2021-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/217944-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/217944-
Descrição: dc.descriptionObjetivo: pH ácido pode alterar propriedades de cimentos reparadores. Este estudo avaliou a alteração volumétrica do cimento reparador biocerâmico pronto para uso Bio-C Repair (BCR, Angelus, Londrina, PR, Brasil) após imersão em solução salina tamponada com fosfato (PBS) (pH 7.0) ou ácido butírico (pH 4.5). Metodologia: Dentes bovinos extraídos foram utilizados para confecção de tubos de dentina com 4 mm de comprimento, diâmetro interno de 1,5 mm e espessura das paredes de aproximadamente 1 mm. Os tubos de dentina foram preenchidos com BCR (n=8) e mantidos em estufa a 37 °C por 24 horas. Escaneamento inicial em microtomografia computadorizada (micro-CT; SkyScan 1176, Bruker, Kontich, Bélgica) com tamanho de voxel de 8.74 µm foi realizado. Em seguida, os espécimes foram imersos em 1,5 mL de PBS ou ácido butírico e mantidos em estufa a 37°C por 7 dias. Após esse período, novo escaneamento em micro-CT foi realizado. Resultados: Bio-C Repair apresentou perda volumétrica após imersão em ácido butírico, e aumento de volume após imersão em PBS (p<0.05). As regiões analisadas (extremidade e parte interna) mostraram comportamento volumétrico semelhante para os dois meios de imersão (p>0.05). Conclusões: O pH ácido influencia a estabilidade dimensional do cimento Bio-C Repair, promovendo perda volumétrica.-
Descrição: dc.descriptionObjective: Acidic pH can modify the properties of repair cements. This study evaluated the volumetric change of the ready-to-use bioceramic repair cement Bio-C Repair (BCR, Angelus, Londrina, PR, Brazil) after immersion in phosphate-buffered saline (PBS) (pH 7.0) or butyric acid (pH 4.5). Methodology: Extracted bovine teeth were used to make dentin tubes with a length of 4 mm, an internal diameter 1.5 mm and wall thickness of approximately 1 mm. The dentin tubes were filled with BCR (n=8) and kept in oven at 37 °C for 24 hours. Initial scanning in micro-computed tomography (micro-CT; SkyScan 1176, Bruker, Kontich, Belgium) with a voxel size of 8.74 µm was performed. Then, the specimens were immersed in 1.5 mL of PBS or butyric acid and kept in oven at and 37 °C for 7 days. After this period, a new micro-CT scan was performed. Results: Bio-C Repair showed a volumetric loss after immersion in butyric acid, and volume increase after immersion in PBS (p<0.05). The analyzed regions (extremity and internal par t) showed similar volumetric behavior for the two immersion media (p>0.05). Conclusion: The acidic pH influences the volumetric stability of Bio-C Repair cement, promoting volumetric loss.-
Descrição: dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
Descrição: dc.descriptionCNPq: 132179/2020-2-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (Unesp)-
Direitos: dc.rightsAcesso restrito-
Direitos: dc.rightsLOCKSS system has permission to collect, preserve, and serve this Archival Unit-
Palavras-chave: dc.subjectEndodontia-
Palavras-chave: dc.subjectMateriais dentários-
Palavras-chave: dc.subjectMicrotomografia por raio-x-
Palavras-chave: dc.subjectPropriedades físicas-
Palavras-chave: dc.subjectEndodontics-
Palavras-chave: dc.subjectDental materials-
Palavras-chave: dc.subjectX-ray microtomography-
Palavras-chave: dc.subjectPhysical properties-
Título: dc.titleAlteração volumétrica do cimento reparador Bio-C Repair em diferentes condições de pH-
Título: dc.titleVolumetric change of Bio-C Repair repair cement in different pH conditions-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.