Avaliação in vitro da acurácia da técnica cirúrgica parcialmente e totalmente guiada para instalação de implantes imediatos em alvéolos

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorBarcelos, Daniela Leal Zandim [UNESP]-
Autor(es): dc.contributorBorges Filho, Fausto Frizzera-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorCalazans, Nicolas Nicchio Nicolini-
Data de aceite: dc.date.accessioned2022-08-04T21:56:09Z-
Data de disponibilização: dc.date.available2022-08-04T21:56:09Z-
Data de envio: dc.date.issued2022-04-14-
Data de envio: dc.date.issued2022-04-14-
Data de envio: dc.date.issued2022-03-16-
Data de envio: dc.date.issued2021-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/217853-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/217853-
Descrição: dc.descriptionA necessidade de substituir um dente logo após a sua extração tem sido observada com frequência. Os implantes imediatos vieram para suprir essa demanda e novas tecnologias que possibilitam a realização do planejamento cirúrgico virtual surgiram, aumentando a previsibilidade do procedimento cirúrgico. Este trabalho teve como objetivo avaliar a acurácia da técnica cirúrgica parcial e totalmente guiada para instalação de implantes imediatos em alvéolos e comparar duas diferentes metodologias de análise de desvios no posicionamento dos implantes. Dez mandíbulas de porco foram selecionadas para a instalação de 20 implantes em alvéolos frescos. Duas técnicas cirúrgicas foram avaliadas: parcialmente guiada (PG) e totalmente guiada (TG). As tomografias computadorizadas e os escaneamentos das mandíbulas foram realizadas previamente e posteriormente à instalação dos implantes para possibilitar o planejamento virtual e a confecção das guias, assim como para avaliar desvios no posicionamento dos implantes. Duas metodologias foram utilizadas para análise dos desvios: tomográfica e escaneamento digital. Na análise tomográfica, constatou-se que o desvio global apical e de profundidade foram significativamente maiores na técnica PG do que na TG. Já na análise por escaneamento, a técnica PG apresentou um desvio global apical, lateral apical e angular significativamente maiores que a TG. Quando comparadas as duas metodologias de análise dos desvios, observou-se uma diferença significativa entre as mesmas no desvio de profundidade. Conclui-se que a técnica TG apresenta maior acurácia no posicionamento dos implantes imediatos em alvéolos frescos do que a PG. Com relação as metodologias para análises de desvio, um menor desvio na profundidade foi observado com a análise tomográfica. Porém, mais estudos são necessários para determinação da melhor metodologia de análise a ser aplicada.-
Descrição: dc.descriptionThe need to replace a tooth soon after its extraction has been frequently observed. Immediate implants came to meet this demand and new technologies that allows the realization of virtual surgical planning have emerged increasing the predictability of the surgical procedure. The aim of the present study was to assess the accuracy of partially and fully guided surgical technique for the installation of immediate implants in alveolar sockets, and to compare two different methodologies for implant position deviations analysis. Ten pig jaws were selected to install 20 implants in fresh alveolar sockets. Two techniques were assessed: Partially guided (PG) and Fully guided (FG). Computed tomography and digital scan were performed before and after the surgical procedure to enable the virtual implant position planning and the surgical guide fabrication, as well as to determine implant position deviations. Two methods were used to evaluate implant deviations: tomographic and digital scanning. In the tomographic analysis, the PG technique resulted in significantly higher global apical and depth deviations than the FG technique. The analysis performed using digital scanning showed significantly higher global apical, lateral apical and angular deviations with the PG technique than with the FG. When comparing the two methodologies used form implant deviation analysis, there was a statistically significant difference between them in the depth deviation. It was concluded that the FG technique provided more accuracy for the installation of immediate implants in fresh alveolar sockets than the PG technique. Regarding the methodologies used for implant deviation analysis, a significantly lower implant depth deviation was observed with the tomographic analysis. However, more studies are necessary to confirm the best methodology to be used for implant deviation analysis.-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
Descrição: dc.description88887.481177/2020-00-
Descrição: dc.descriptionCAPES: 001-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (Unesp)-
Direitos: dc.rightsAcesso restrito-
Direitos: dc.rightsLOCKSS system has permission to collect, preserve, and serve this Archival Unit-
Palavras-chave: dc.subjectImplantação Dentária-
Palavras-chave: dc.subjectCirurgia assistida por computador-
Palavras-chave: dc.subjectTomografia-
Palavras-chave: dc.subjectDental Implantation-
Palavras-chave: dc.subjectSurgery-
Palavras-chave: dc.subjectComputer-Assisted-
Palavras-chave: dc.subjectTomography.-
Título: dc.titleAvaliação in vitro da acurácia da técnica cirúrgica parcialmente e totalmente guiada para instalação de implantes imediatos em alvéolos-
Título: dc.titleIn vitro assessment of the accuracy of partially and fully guided surgical technique for immediate implant placement in alveolar sockets-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.