Avaliação das propriedades de superfície, mecânicas e ópticas de resinas acrílicas de base de dentadura confeccionadas pelo método CAD-CAM com processo de envelhecimento e imersão em bebidas corantes.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorPellizzer, Eduardo Piza [UNESP]-
Autor(es): dc.contributorSantos, Daniela Micheline dos [UNESP]-
Autor(es): dc.contributorLemos, Cleidiel Aparecido Araújo [UNESP]-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorBento, Victor Augusto Alves [UNESP]-
Data de aceite: dc.date.accessioned2022-08-04T21:53:38Z-
Data de disponibilização: dc.date.available2022-08-04T21:53:38Z-
Data de envio: dc.date.issued2022-02-28-
Data de envio: dc.date.issued2022-02-28-
Data de envio: dc.date.issued2022-02-23-
Data de envio: dc.date.issued2021-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/216950-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/216950-
Descrição: dc.descriptionO objetivo desse estudo foi investigar as propriedades de superfície, estabilidade de cor e propriedades mecânicas de resinas acrílicas para base de dentadura do método convencional, processada por micro-ondas, fresada e impressa 3D diante de diferentes tempos de envelhecimento e imersão em bebidas corantes. Além disso, realizar uma revisão sistemática para avaliar e comparar, através de estudos de ensaios clínicos, próteses totais fabricadas pelo método CAD/CAM com fabricadas convencionalmente, em termos de tempo clínico, manutenção, retenção, estabilidade, eficácia mastigatória, satisfação e qualidade de vida. Um total de 480 amostras redondas (10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades de superfície e estabilidade de cor, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3) e bebidas corantes (água, café, vinho e refrigerante cola), resultando um n = 10 para cada subgrupo. Um total de 160 amostras retangulares (64 × 10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades mecânicas, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3), resultando um n = 10 para cada subgrupo. A revisão sistemática seguiu os Itens de Relatório Preferenciais para Revisões Sistemáticas e Meta-Análises (PRISMA) e foi registrada no Registro Prospectivo Internacional de Revisões Sistemáticas (PROSPERO) (CRD42022296907). A busca eletrônica foi realizada nas bases de dados PubMed/MEDLINE, Web of Science e Scopus até dezembro de 2021. A questão formulada para população, intervenção, comparação e resultado (PICO) foi “Pacientes reabilitados com próteses totais com tecnologia CAD/CAM apresentam parâmetros clínicos semelhantes aos pacientes reabilitados com próteses totais convencionais?”. A resina fresada apresentou os melhores resultados das propriedades de superfície diante do efeito do envelhecimento, enquanto que a resina impressa 3D apresentou resultados semelhantes as resinas tradicionais. A resina de Impressão 3D apresentou não ter propriedades ópticas adequadas diante do efeito do envelhecimento, enquanto que a resina fresada apresentou as melhores propriedades. As bebidas corantes não alteraram as propriedades de superfície das resinas, entretanto afetaram suas propriedades ópticas, principalmente a resina de impressão 3D e a processada por micro-ondas. A resina de dentadura fresada CAD/CAM apresentou propriedades mecânicas semelhantes as resinas tradicionais, enquanto que a impressa 3D não apresentou propriedades mecânicas adequadas para uso clínico à longo prazo. As próteses do método de fresagem apresentaram melhor desempenho clínico que as próteses convencionais, em termos de qualidade de vida, satisfação, retenção, estabilidade, tempo clínico e custo, enquanto que as de impressão 3D não apresentaram diferenças. Ambos os métodos do CAD/CAM apresentaram não haver diferenças da eficácia mastigatória em relação as próteses convencionais.-
Descrição: dc.descriptionThe objective of this study was to investigate the surface properties, color stability and mechanical properties of acrylic resins for denture base of the conventional method, processed by microwave, milled and 3D printed in face of different aging times and immersion in coloring drinks. In addition, carry out a systematic review to evaluate and compare, through clinical trial studies, complete dentures manufactured by the CAD/CAM method with those manufactured conventionally, in terms of clinical time, maintenance, retention, stability, masticatory efficiency, satisfaction and quality of life. A total of 480 round samples (10 × 3.3 ± 0.03 mm) were made to evaluate surface properties and color stability, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3) and coloring drinks (water, coffee, wine and cola), resulting in n = 10 for each subgroup. A total of 160 rectangular samples (64 × 10 × 3.3 ± 0.03 mm) were prepared to evaluate the mechanical properties, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3), resulting in n = 10 for each subgroup. The systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the International Prospective Registry of Systematic Reviews (PROSPERO) (CRD42022296907). The electronic search was performed in the PubMed/MEDLINE, Web of Science and Scopus databases until December 2021. The question formulated for population, intervention, comparison and result (PICO) was “Patients rehabilitated with complete dentures with CAD/CAM technology present clinical parameters similar to patients rehabilitated with conventional complete dentures?”. The milled resin presented the best results of surface properties in the face of aging effect, while the 3D printed resin presented similar results to traditional resins. The 3D Printing resin did not have adequate optical properties due to the aging effect, while the milled resin showed the best properties. Coloring drinks do not change the surface properties of resins, but optical printing solutions, mainly 3D printing resin and microwave-processed resin. The CAD/CAM milled denture resin presented mechanical properties similar to traditional resins, while the 3D printed denture resin did not present adequate mechanical properties for long-term clinical use. The milling method prostheses showed better clinical performance than conventional prostheses, in terms of quality of life, satisfaction, retention, stability, clinical time and cost, while the 3D printing prostheses showed no differences. Both CAD/CAM methods showed no differences in masticatory efficiency in relation to conventional prostheses.-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (Unesp)-
Direitos: dc.rightsAcesso aberto-
Direitos: dc.rightsLOCKSS system has permission to collect, preserve, and serve this Archival Unit-
Palavras-chave: dc.subjectPrótese dentária-
Palavras-chave: dc.subjectBases de dentadura-
Palavras-chave: dc.subjectPolimetil metacrilato-
Palavras-chave: dc.subjectDesenho assistido por computador-
Palavras-chave: dc.subjectDental prosthesis-
Título: dc.titleAvaliação das propriedades de superfície, mecânicas e ópticas de resinas acrílicas de base de dentadura confeccionadas pelo método CAD-CAM com processo de envelhecimento e imersão em bebidas corantes.-
Título: dc.titleEvaluation of surface, mechanical and optical properties of denture base acrylic resins made by the CAD-CAM method with aging process and immersion in coloring drinks.-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.