Silica-Nylon Reinforcement Effect on the Fracture Load and Stress Distribution of a Resin-Bonded Partial Dental Prosthesis

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorUniv Amsterdam-
Autor(es): dc.contributorVrije Univ-
Autor(es): dc.creatorFirmino, Aline Silva [UNESP]-
Autor(es): dc.creatorTribst, Joao Paulo Mendes-
Autor(es): dc.creatorNakano, Leonardo Jiro Nomura [UNESP]-
Autor(es): dc.creatorDal Piva, Amanda Maria de Oliveira-
Autor(es): dc.creatorBorges, Alexandre Luiz Souto-
Autor(es): dc.creatorArruda Paes-Junior, Tarcisio Jose [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:59:09Z-
Data de disponibilização: dc.date.available2022-02-22T00:59:09Z-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-03-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.11607/prd.4347-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/210202-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/210202-
Descrição: dc.descriptionThis study investigated the influence of silica-nylon reinforcement on the stress distribution and fracture load of a resin-bonded fixed partial dental prosthesis (RBFDP). Three-unit RBFDPs (N = 60) were inserted between the first premolar and the first molar of a maxillary model. The groups were divided according to the nylon reinforcement (n = 20/group): conventional fixed prosthesis (without reinforcement), prosthesis with silica-nylon reinforcement positioned vertically, and prosthesis with silica-nylon reinforcement positioned horizontally. Half of the specimens were tested after 24 hours in a universal testing machine until fracture (1,000 kgf; 1 mm/minute) to determine the single load to fracture. The other half was submitted to mechanical aging during 10(6) cycles (100 N, 2 Hz), totaling 6 groups (n = 10/group). The results were analyzed by two-way analysis of variance (ANOVA; alpha = 5%). The stress distribution for non-aged groups was simulated using finite element analysis. The numeric prostheses were modeled similarly to the in vitro assay. ANOVA showed no statistical difference between groups (P<.05) for load to fracture. However, the use of the reinforcement provided stability even after the failure, as the parts did not separate. The computational analysis showed similar biomechanical behavior among the groups. The use of the nylon reinforcement does not influence the fracture load or the stress distribution, but it does enable the prosthesis to remain in position after failure.-
Descrição: dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
Descrição: dc.descriptionSao Paulo State Univ UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, Brazil-
Descrição: dc.descriptionUniv Amsterdam, Acad Ctr Dent Amsterdam, Dept Dent Mat Sci, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands-
Descrição: dc.descriptionVrije Univ, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands-
Descrição: dc.descriptionSao Paulo State Univ UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, Brazil-
Descrição: dc.descriptionFAPESP: 11/07334-6-
Formato: dc.formatE45-E54-
Idioma: dc.languageen-
Publicador: dc.publisherQuintessence Publishing Co Inc-
Relação: dc.relationInternational Journal Of Periodontics & Restorative Dentistry-
???dc.source???: dc.sourceWeb of Science-
Título: dc.titleSilica-Nylon Reinforcement Effect on the Fracture Load and Stress Distribution of a Resin-Bonded Partial Dental Prosthesis-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.