Analysis of transient voltages and currents in short transmission lines on frequency-dependent soils☆

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorUniversidade Estadual de Campinas (UNICAMP)-
Autor(es): dc.creatorPascoalato, T. F.G. [UNESP]-
Autor(es): dc.creatorde Araújo, A. R.J.-
Autor(es): dc.creatorKurokawa, S. [UNESP]-
Autor(es): dc.creatorPissolato Filho, J.-
Data de aceite: dc.date.accessioned2022-02-22T00:53:23Z-
Data de disponibilização: dc.date.available2022-02-22T00:53:23Z-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-05-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1016/j.epsr.2021.107103-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/208428-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/208428-
Descrição: dc.descriptionAccurate modeling of overhead transmission lines (OHTLs) for transient analysis require that the ground which the phase conductors are suspended be considered on the longitudinal impedance and transversal admittance matrices. In this framework, some models deal with the soil as an ideal conductor (constant resistivity ρg and relative permittivity εr). However, it is known fact that real soils are characterized by frequency-dependent (FD) electrical parameters (ρg(f) and εr(f)). Due to these conditions, different formulations to represent the soil with FD parameters have been developed in the last decades. In order to obtain a precise transient response, these models must be incorporated in longitudinal impedance, as the ground-return impedance, and transversal admittance matrices. In this article, an analysis to compute the impact of some FD soil electrical parameters on transient responses is carried out. These responses are calculated for an energization maneuver and ligtning direct strike on OHTLs with different lengths located above constant and FD soil parameter models of low and high soil resistive values. Results show significant differences between the transient responses obtained with the constant and FD soil models, which these variations are more pronounced for soils of high resistivity and for short OHTLs.-
Descrição: dc.descriptionSão Paulo State University (UNESP)-
Descrição: dc.descriptionUniversity of Campinas-
Descrição: dc.descriptionSão Paulo State University (UNESP)-
Idioma: dc.languageen-
Relação: dc.relationElectric Power Systems Research-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectElectromagnetic transients-
Palavras-chave: dc.subjectfrequency-dependent soils-
Palavras-chave: dc.subjectground-return impedance-
Palavras-chave: dc.subjecttransmission lines-
Título: dc.titleAnalysis of transient voltages and currents in short transmission lines on frequency-dependent soils☆-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.