Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.contributor | Aalto University | - |
Autor(es): dc.creator | Melgar-Dominguez, Ozy D. [UNESP] | - |
Autor(es): dc.creator | Mantovani, Jose R. S. [UNESP] | - |
Autor(es): dc.creator | Pourakbari-Kasmaei, Mahdi | - |
Autor(es): dc.creator | Lehtonen, Matti | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:52:46Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:52:46Z | - |
Data de envio: dc.date.issued | 2021-06-25 | - |
Data de envio: dc.date.issued | 2021-06-25 | - |
Data de envio: dc.date.issued | 2020-10-25 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1109/ISGT-Europe47291.2020.9248813 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/208220 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/208220 | - |
Descrição: dc.description | This work aims at proposing a strategy based on an environmental and technical perspective to assess the amount of distributed generation (DG) that can be deployed into an electric distribution network (EDN). The presented approach seeks to minimize the carbon emissions and energy losses while the installed capacity of renewable DG units is maximized. To enable the DG integration without requiring EDN upgrading, the operations of capacitor banks (CBs) and voltage regulators (VR) devices are optimized simultaneously. To analyze the relationship between the installed DG and demand consumption, the effects of voltage-dependent loads are investigated. Several test cases are studied in a 42-node distribution network. Results show that by applying operating actions and determining the hosting capacity of the EDN for deploying DG units, environmental and technical benefits could be achieved. | - |
Descrição: dc.description | São Paulo State University (UNESP) Department of Electrical Engineering | - |
Descrição: dc.description | Aalto University Department of Electrical Engineering and Automation | - |
Descrição: dc.description | São Paulo State University (UNESP) Department of Electrical Engineering | - |
Formato: dc.format | 1010-1014 | - |
Idioma: dc.language | en | - |
Relação: dc.relation | IEEE PES Innovative Smart Grid Technologies Conference Europe | - |
???dc.source???: dc.source | Scopus | - |
Palavras-chave: dc.subject | DG hosting capacity | - |
Palavras-chave: dc.subject | Emissions reduction | - |
Palavras-chave: dc.subject | Exponential demand model | - |
Título: dc.title | Increasing distributed generation hosting capacity in distribution networks: A CO2emission analysis | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: