Dry Ashing for Signal Enhancement in Laser-Induced Breakdown Spectroscopy (LIBS)

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorCNR-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.creatorLázaro, Maisa Cristina [UNESP]-
Autor(es): dc.creatorMorais, Carla Pereira de [UNESP]-
Autor(es): dc.creatorSilva, Tiago Varão [UNESP]-
Autor(es): dc.creatorSenesi, Giorgio Saverio-
Autor(es): dc.creatorJúnior, Dário Santos-
Autor(es): dc.creatorNeto, José Anchieta Gomes [UNESP]-
Autor(es): dc.creatorFerreira, Edilene Cristina [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:52:15Z-
Data de disponibilização: dc.date.available2022-02-22T00:52:15Z-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2020-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1080/00032719.2020.1833021-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/208046-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/208046-
Descrição: dc.descriptionLimited sensitivities of some laser-induced breakdown spectroscopy (LIBS) instruments may impair some applications. Although this drawback can be minimized by instrumental improvements, the complexity of operations and cost increases. In this work the principle of conventional dry ashing for sample preparation was evaluated as a simple and low-cost alternative to improve the sensitivity of LIBS analysis. Botanical, agronomic and industrial samples were analyzed. Samples were dry heated and their LIBS emission signals were evaluated. The results suggest the dry heating caused structural changes in samples providing greater availability of the analyte, which resulted in the enhancement of the signals. As proof of concept, the strategy was applied for Sr determination in plant leaves. Two Sr emission lines, enhanced after sample dry ashing were used. The developed methods showed similar performance featuring a good linear range (10 to 70 μg g−1) with coefficient of correlations higher than 0.99. Additionally, the accurate determination of Sr in apple and peach leaves standard materials was achieved.-
Descrição: dc.descriptionDepartment of Analytical Physical-Chemical and Inorganic Chemistry São Paulo State University - UNESP-
Descrição: dc.descriptionIstituto per la Scienza e Tecnologia dei Plasmi (ISTP) Sede di Bari CNR-
Descrição: dc.descriptionExact and Earth Sciences Department Federal University of São Paulo - UNIFESP-
Descrição: dc.descriptionDepartment of Analytical Physical-Chemical and Inorganic Chemistry São Paulo State University - UNESP-
Formato: dc.format2009-2021-
Idioma: dc.languageen-
Relação: dc.relationAnalytical Letters-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDry ashing-
Palavras-chave: dc.subjectdry heating-
Palavras-chave: dc.subjectlaser-induced breakdown spectroscopy (LIBS)-
Palavras-chave: dc.subjectsensitivity-
Título: dc.titleDry Ashing for Signal Enhancement in Laser-Induced Breakdown Spectroscopy (LIBS)-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp