Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | IPPortalegre—Polytechnic Institute of Portalegre | - |
Autor(es): dc.contributor | MEtRICs—Mechanical Engineering and Resource Sustainability Center | - |
Autor(es): dc.contributor | Universidad de Jaen | - |
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.contributor | Polytechnic Institute of Portalegre | - |
Autor(es): dc.creator | Mota-Panizio, Roberta | - |
Autor(es): dc.creator | Hermoso-Orzáez, Manuel Jesús | - |
Autor(es): dc.creator | Carmo-Calado, Luís | - |
Autor(es): dc.creator | de Campos, Victor Arruda Ferraz [UNESP] | - |
Autor(es): dc.creator | Silveira, José Luz [UNESP] | - |
Autor(es): dc.creator | Gonçalves, Maria Margarida | - |
Autor(es): dc.creator | Brito, Paulo | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:48:25Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:48:25Z | - |
Data de envio: dc.date.issued | 2021-06-25 | - |
Data de envio: dc.date.issued | 2021-06-25 | - |
Data de envio: dc.date.issued | 2020-11-01 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.3390/app10228253 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/206854 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/206854 | - |
Descrição: dc.description | The recovery of noble metals from electrical wires and cables results in waste materials such as polyvinyl chloride (PVC) and polyethylene (PE), that is, waste insulation electrical cables (WIEC), which have been processed by gasification for energy recovery. This study focused on the effect of blending the ratio of WIEC on the gasification feedstock composition and the lower heating value (LHV) of produced syngas, through controlled tests and tests under different loads on the generator. The controlled gasification experiments were carried out at blending ratios between pine biomass and WIEC of 90:10, 80:20, and 70:30 and with pine biomass only (100%). For the loads gasification, the experiments were carried out at a blending ratio of 80:20. The controlled experimental results presented that the highest hydrogen content, approximated 17.7 vol.%, was observed at a blending ratio of 70:30 between pine biomass and WIEC and the highest LHV of syngas was observed at a blending ratio of 90:10, with 5.7 MJ/Nm3. For the load gasification experiments, the results showed that the highest hydrogen content was obtained with a load of 15 kW in the generator, approximately 18.48 vol.% of hydrogen content, and the highest LHV of synthesis gas was observed during the 5 kW test, with 5.22 MJ/Nm3. Overall, the new processing of waste insulation electrical cables using a downdraft gasification reactor demonstrates great promise for high quality syngas production. | - |
Descrição: dc.description | European Regional Development Fund | - |
Descrição: dc.description | Fundação para a Ciência e a Tecnologia | - |
Descrição: dc.description | IPPortalegre—Polytechnic Institute of Portalegre | - |
Descrição: dc.description | Department of Science and Technology of Biomass Universidade NOVA de Lisboa Faculty of Science and Technology MEtRICs—Mechanical Engineering and Resource Sustainability Center | - |
Descrição: dc.description | Department of Graphic Engineering Design and Projects Universidad de Jaen | - |
Descrição: dc.description | Department of Energy Faculty of Engineering of Guaratinguetá Institute of Bioenergy Research (IPBEN-UNESP)—Associated Laboratory of Guaratinguetá Laboratory of Optimization of Energy Systems (LOSE) São Paulo State University UNESP | - |
Descrição: dc.description | VALORIZA—Research Center for Endogenous Resource Valorization Polytechnic Institute of Portalegre | - |
Descrição: dc.description | Department of Energy Faculty of Engineering of Guaratinguetá Institute of Bioenergy Research (IPBEN-UNESP)—Associated Laboratory of Guaratinguetá Laboratory of Optimization of Energy Systems (LOSE) São Paulo State University UNESP | - |
Descrição: dc.description | Fundação para a Ciência e a Tecnologia: 88881.156267/2017-01 | - |
Formato: dc.format | 1-19 | - |
Idioma: dc.language | en | - |
Relação: dc.relation | Applied Sciences (Switzerland) | - |
???dc.source???: dc.source | Scopus | - |
Palavras-chave: dc.subject | Biofuel | - |
Palavras-chave: dc.subject | Energy recovery | - |
Palavras-chave: dc.subject | Gasification | - |
Palavras-chave: dc.subject | Waste insulation electrical cables | - |
Palavras-chave: dc.subject | WEEE | - |
Título: dc.title | Energy recovery via thermal gasification from waste insulation electrical cables (Wiec) | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: