The influence of a liner on deep bulk-fill restorations: Randomized clinical trial

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorTorres, Carlos Rocha Gomes [UNESP]-
Autor(es): dc.creatorMailart, Mariane Cintra [UNESP]-
Autor(es): dc.creatorRocha, Rafael Santos [UNESP]-
Autor(es): dc.creatorSellan, Pablo Lenin Benitez [UNESP]-
Autor(es): dc.creatorContreras, Sheila Célia Mondragón [UNESP]-
Autor(es): dc.creatorDi Nicoló, Rebeca [UNESP]-
Autor(es): dc.creatorBorges, Alessandra Bühler [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:47:31Z-
Data de disponibilização: dc.date.available2022-02-22T00:47:31Z-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2021-06-25-
Data de envio: dc.date.issued2020-10-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1016/j.jdent.2020.103454-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/206576-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/206576-
Descrição: dc.descriptionObjective: The aim of this study was to evaluate the influence of a liner on the clinical performance of deep posterior restorations performed with bulk-fill composite. Methods: 30 subjects received two restorations on deep preparations in posterior teeth, without pulpal exposure, after selective carious-tissue removal in one-stage. The internal walls reached the inner quarter of dentin, but with a radiographically detectable zone of firm dentin remaining. The pulpal protection using a layer of glass ionomer composite liner (Ionoseal, Voco) was applied in just one preparation. The adhesive system Futurabond U (Voco) was applied in all preparations, which were restored with the bulk-fill pure Ormocer nanohybrid composite (Admira Fusion Xtra - Voco), in up to 4 mm thick increments. All restorations were evaluated using the FDI criteria after 7 days, 6, 12 and 24 months postoperatively. Results: After 24-months, 25 patients attended the recall and 50 restorations were evaluated. The Fisher's statistical analysis (5%) showed no difference between the techniques for the esthetic, functional and biological properties. No postoperative sensitivity was reported for both groups. Conclusion: The application of a liner did not influence the clinical performance of deep restorations with bulk-fill Ormocer composite. Clinical relevance: The application of a liner with a GIC-based material did not have a significant effect on the clinical performance of bulk-fill restorations and seems to be unnecessary for the material tested.-
Descrição: dc.descriptionSao Paulo State University - UNESP Institute of Science and Technology Department of Restorative Dentistry, São José Dos Campos, Avenida Engenheiro Francisco José Longo, 777, Jardim São Dimas-
Descrição: dc.descriptionSao Paulo State University - UNESP Institute of Science and Technology Department of Restorative Dentistry, São José Dos Campos, Avenida Engenheiro Francisco José Longo, 777, Jardim São Dimas-
Idioma: dc.languageen-
Relação: dc.relationJournal of Dentistry-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectBulk-fill-
Palavras-chave: dc.subjectGlass ionomer cement-
Palavras-chave: dc.subjectLiner-
Palavras-chave: dc.subjectOrmocer-
Palavras-chave: dc.subjectPulp Protection-
Título: dc.titleThe influence of a liner on deep bulk-fill restorations: Randomized clinical trial-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.