Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.creator | Marcelo, Alexandre Borges [UNESP] | - |
Autor(es): dc.creator | De Andrade Alves Santos, Risomar [UNESP] | - |
Autor(es): dc.creator | Tirolli, Marcelo Nogueira [UNESP] | - |
Autor(es): dc.creator | Zeneratto, Davi Fernando Lopes Vieira [UNESP] | - |
Autor(es): dc.creator | Marafao, Fernando Pinhabel [UNESP] | - |
Autor(es): dc.creator | Goncalves, Flavio Alessandro Serrao [UNESP] | - |
Autor(es): dc.creator | Paredes, Helmo Kelis Morales [UNESP] | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:34:08Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:34:08Z | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2018-06-25 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1109/SBSE.2018.8395758 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/201649 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/201649 | - |
Descrição: dc.description | In this article the CPC theory was implemented in simulation environment with the intention of discussing its application in different circuits and operating conditions. The analyzed conditions focus on three-phase three-wire systems, starting from sinusoidal supply with symmetrical voltages, balanced and unbalanced, linear and non-linear loads, evolving to asymmetric and non-sinusoidal supply voltage using the same load configurations. As a result of these possible variations, which represent the diversity in current electrical systems, it is necessary to survey, study and implement increasingly complex algorithms, in order to cover all these possibilities. The Currents' Physical Components theory was coherent for all circuits with linear time-invariant loads. For non-linear loads, however, there were unexpected power components, that is, they did not match their suggested physical interpretation. Therefore, further studies of these cases are necessary. | - |
Descrição: dc.description | Institute of Science and Technology São Paulo State University - UNESP | - |
Descrição: dc.description | Institute of Science and Technology São Paulo State University - UNESP | - |
Formato: dc.format | 1-6 | - |
Idioma: dc.language | pt_BR | - |
Relação: dc.relation | SBSE 2018 - 7th Brazilian Electrical Systems Symposium | - |
???dc.source???: dc.source | Scopus | - |
Palavras-chave: dc.subject | Currents' Physical Components (CPC) | - |
Palavras-chave: dc.subject | Non-sinusoidal and/or Unbalanced Systems | - |
Palavras-chave: dc.subject | Power Theories | - |
Título: dc.title | Currents' physical components (CPC): Case studies in three phase systems | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: