Study of the influence of temperature on low-cost piezoelectric transducer response for 3d printing process monitoring

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorLopes, Thiago Glissoi [UNESP]-
Autor(es): dc.creatorRocha, Renata Maia [UNESP]-
Autor(es): dc.creatorAguiar, Paulo Roberto De [UNESP]-
Autor(es): dc.creatorAlexandre, Felipe Aparecido [UNESP]-
Autor(es): dc.creatorConceicao, Pedro De Oliveira [UNESP]-
Autor(es): dc.creatorViera, Martin Antonio Aulestia [UNESP]-
Autor(es): dc.creatorFranca, Thiago Valle [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:33:40Z-
Data de disponibilização: dc.date.available2022-02-22T00:33:40Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2019-10-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1109/IESTEC46403.2019.00103-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/201483-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/201483-
Descrição: dc.descriptionThe pencil lead break method (PLB) is widely used on account of its efficiency in the characterization of acoustic emission sensors (AE), which are used in the monitoring of structures. The piezoelectric diaphragm (PZT) has been studied in recent years as an alternative to conventional AE sensors. The present work aims to study the influence of temperature on the piezoelectric diaphragm response for the monitoring of the 3D printing process. Fifteen PLB tests were performed on the glass surface of a 3D printer at three different temperatures. The results demonstrate that the frequency response of the sensor is directly influenced by the temperature variations. When comparing the frequency response of the signals obtained at different temperatures, it was possible to identify frequency bands that were not altered by the temperature variations. Thus, based on the results of this study, the 3D printing process can be monitored through the PZT diaphragm signals, along with the application of digital filters and signal processing.-
Descrição: dc.descriptionDepartment of Electrical Engineering São Paulo State University - UNESP-
Descrição: dc.descriptionDepartment of Electrical Engineering São Paulo State University - UNESP-
Formato: dc.format544-549-
Idioma: dc.languagees-
Relação: dc.relationProceedings - 2019 7th International Engineering, Sciences and Technology Conference, IESTEC 2019-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subject3D printing-
Palavras-chave: dc.subjectPencil lead break method-
Palavras-chave: dc.subjectProcess monitoring-
Palavras-chave: dc.subjectTemperature-
Título: dc.titleStudy of the influence of temperature on low-cost piezoelectric transducer response for 3d printing process monitoring-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.