Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorTribst, João Paulo Mendes [UNESP]-
Autor(es): dc.creatorDal Piva, Amanda Maria de Oliveira [UNESP]-
Autor(es): dc.creatorBorges, Alexandre Luiz Souto [UNESP]-
Autor(es): dc.creatorBottino, Marco Antonio [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:33:38Z-
Data de disponibilização: dc.date.available2022-02-22T00:33:38Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-04-25-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1080/10255842.2019.1710833-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/201469-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/201469-
Descrição: dc.descriptionThis study evaluated the bone microstrain, displacement, and stress distribution according to the surgical technique (conventional or Socket-shield) and evaluation period (immediately after implant installation or after healing). Each condition was modeled for the finite element analysis, totaling four groups, with a morse-taper implant and a cemented prosthesis. The maximum displacement, von Mises stress, and bone microstrain yielded higher values during the immediate stage, without a difference between Socket-shield and conventional treatments. The use of the Socket-shield technique does not negatively impact the biomechanical behavior of an implant-supported prosthesis immediately after healing from the implant installation.-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP)-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP)-
Formato: dc.format224-231-
Idioma: dc.languageen-
Relação: dc.relationComputer Methods in Biomechanics and Biomedical Engineering-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectFinite element analysis-
Palavras-chave: dc.subjectimplants-
Palavras-chave: dc.subjectprosthetic dentistry-
Título: dc.titleInfluence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis-
Tipo de arquivo: dc.typelivro digital-