Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.creator | Tribst, João Paulo Mendes [UNESP] | - |
Autor(es): dc.creator | Dal Piva, Amanda Maria de Oliveira [UNESP] | - |
Autor(es): dc.creator | Borges, Alexandre Luiz Souto [UNESP] | - |
Autor(es): dc.creator | Bottino, Marco Antonio [UNESP] | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:33:38Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:33:38Z | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2020-04-25 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1080/10255842.2019.1710833 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/201469 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/201469 | - |
Descrição: dc.description | This study evaluated the bone microstrain, displacement, and stress distribution according to the surgical technique (conventional or Socket-shield) and evaluation period (immediately after implant installation or after healing). Each condition was modeled for the finite element analysis, totaling four groups, with a morse-taper implant and a cemented prosthesis. The maximum displacement, von Mises stress, and bone microstrain yielded higher values during the immediate stage, without a difference between Socket-shield and conventional treatments. The use of the Socket-shield technique does not negatively impact the biomechanical behavior of an implant-supported prosthesis immediately after healing from the implant installation. | - |
Descrição: dc.description | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP) | - |
Descrição: dc.description | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP) | - |
Formato: dc.format | 224-231 | - |
Idioma: dc.language | en | - |
Relação: dc.relation | Computer Methods in Biomechanics and Biomedical Engineering | - |
???dc.source???: dc.source | Scopus | - |
Palavras-chave: dc.subject | Finite element analysis | - |
Palavras-chave: dc.subject | implants | - |
Palavras-chave: dc.subject | prosthetic dentistry | - |
Título: dc.title | Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: