Selective Power Conditioning in Two-Phase Three-Wire Systems Based on the Conservative Power Theory

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorDept. of Electric Power Engineering Norwegian-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorUniversity of Mato Grosso (UFMT)-
Autor(es): dc.contributorUniversidade Federal de Minas Gerais (UFMG)-
Autor(es): dc.creatorAlonso, Augusto M. S.-
Autor(es): dc.creatorParedes, Helmo K. M. [UNESP]-
Autor(es): dc.creatorFilho, José A. O. [UNESP]-
Autor(es): dc.creatorBonaldo, Jakson P.-
Autor(es): dc.creatorBrandão, Danilo I.-
Autor(es): dc.creatorMarafao, Fernando P. [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:33:27Z-
Data de disponibilização: dc.date.available2022-02-22T00:33:27Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2019-09-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1109/IAS.2019.8911909-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/201408-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/201408-
Descrição: dc.descriptionAC power conditioners in electric power systems have been extensively explored in the literature based on approaches mainly focused on single- and three-phase wiring topologies, remaining a significant gap in regard to applications suitable for two-phase three-wire circuitry. Therefore, this work demonstrates that the Conservative Power Theory can be employed to generate the proper reference signals for an active power filter in two-phase three-wire networks. This methodology allows to selectively synthesize reference signals in a flexible manner, providing reactive power compensation, mitigation of unbalance and harmonic currents, as well as contributing to the reduction of neutral current at point of common coupling. The proposed strategy, its implementation, and the control design of a three-leg active power filter are discussed in this paper through simulation results, demonstrating the particularities and advantages of this approach.-
Descrição: dc.descriptionUniversity of Science Technology (NTNU) Dept. of Electric Power Engineering Norwegian-
Descrição: dc.descriptionGroup of Automation and Integrated Systems (GASI) São Paulo State University (UNESP)-
Descrição: dc.descriptionUniversity of Mato Grosso (UFMT) Department of Electrical Engineering Federal-
Descrição: dc.descriptionElectrical Engineering Federal University of Minas Gerais (UFMG)-
Descrição: dc.descriptionGroup of Automation and Integrated Systems (GASI) São Paulo State University (UNESP)-
Idioma: dc.languageen-
Relação: dc.relation2019 IEEE Industry Applications Society Annual Meeting, IAS 2019-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectActive Power Filter-
Palavras-chave: dc.subjectConservative Power Theory-
Palavras-chave: dc.subjectHarmonics-
Palavras-chave: dc.subjectPower Quality-
Palavras-chave: dc.subjectTwo-phase Three-wire-
Palavras-chave: dc.subjectUnbalance-
Título: dc.titleSelective Power Conditioning in Two-Phase Three-Wire Systems Based on the Conservative Power Theory-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.