Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.creator | Colqui, Jaimis S.L. [UNESP] | - |
Autor(es): dc.creator | De Araújo, Anderson R.J. [UNESP] | - |
Autor(es): dc.creator | Kurokawa, Sérgio [UNESP] | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:33:17Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:33:17Z | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2019-11-04 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1049/iet-gtd.2018.6301 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/201336 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/201336 | - |
Descrição: dc.description | A simplified methodology is proposed to reduce numerical oscillations in transient responses when transmission lines are represented by a lumped parameter approach employing a π-circuit cascade. These oscillations cause erroneous peaks in electromagnetic transient simulations, which may lead to incorrect interpretations for users. A modified π-circuit cascade, which consists of inserting a damping resistance in series to the capacitor in the traditional π-circuit cascade, is a known topology in the literature, but its influence on transient responses has not been fully studied. In this study, a methodology is shown for selecting an appropriate adjustable factor to reduce the numerical oscillations for a given transmission line of length l without distorting the transient response. The proposed methodology is applied directly in line modelling, facilitating the selection of the damping resistance. The results obtained from the proposed methodology are compared with inverse numerical Laplace transform responses, which is a well-established technique, and with the traditional lumped parameter model, showing an expressive attenuation of the numerical oscillations in the electromagnetic transient responses. | - |
Descrição: dc.description | São Paulo State University-UNESP | - |
Descrição: dc.description | São Paulo State University-UNESP | - |
Formato: dc.format | 4942-4951 | - |
Idioma: dc.language | en | - |
Relação: dc.relation | IET Generation, Transmission and Distribution | - |
???dc.source???: dc.source | Scopus | - |
Título: dc.title | Improving the performance of a lumped transmission line model used in electromagnetic transient analysis | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: