A novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric study

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorHospital Orto-
Autor(es): dc.contributorÁpice Clinic-
Autor(es): dc.contributorSafrima-
Autor(es): dc.contributorAsklepios Klinik-
Autor(es): dc.contributorSanta Casa de Misericórdia de São Paulo (SCSP)-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorRibeiro, Cristiano Hossri-
Autor(es): dc.creatorMod, Mauricio Sante Bettio-
Autor(es): dc.creatorIsch, Daniel-
Autor(es): dc.creatorBaier, Clemens-
Autor(es): dc.creatorMaderbacher, Guenther-
Autor(es): dc.creatorSeverino, Nilson Roberto-
Autor(es): dc.creatorCataneo, Daniele Cristina [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:32:33Z-
Data de disponibilização: dc.date.available2022-02-22T00:32:33Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-01-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1007/s00402-019-03300-w-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/201086-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/201086-
Descrição: dc.descriptionIntroduction: The complications of the open-wedge osteotomy technique (slope, hypo- and hypercorrection and fractures) are related to difficulties in the control of the open-wedge angle during surgery. Materials and methods: In this cadaveric study, we evaluated the safety and precision of a novel system, the Realignment High Control System (RHC), in the correction of knee mechanical axis and slope. The RHC has a fixation plate coupled to a dynamic device that opens the osteotomy continuously, allowing plate fixation before osteotomy wedge opening. Results: All procedures were easily performed, with no fractures. The openings equaled the indicated by the navigation system for 7.5° and 10°, and for 5°, there was a statistically, although not clinically significant, difference of 0.6°. The slope shown by the RHC setting and in the navigation system was significantly different for the 10° setting only, with a mean difference of 0.563°. Conclusions: RHC facilitates the surgical technique of high tibial osteotomy, with gradual wedge opening, precise correction of the mechanical axis, and appropriate control of the tibial slope, even with larger openings.-
Descrição: dc.descriptionKnee Surgery Division Hospital Orto, Av. Nove de Julho, 1017, Vila Icaraí-
Descrição: dc.descriptionÁpice Clinic-
Descrição: dc.descriptionSafrima-
Descrição: dc.descriptionAsklepios Klinik-
Descrição: dc.descriptionDepartment of Orthopedics and Traumatology Santa Casa de Misericórdia de São Paulo (SCSP)-
Descrição: dc.descriptionSurgery and Orthopaedics Department Universidade Estadual de São Paulo (Unesp)-
Descrição: dc.descriptionSurgery and Orthopaedics Department Universidade Estadual de São Paulo (Unesp)-
Formato: dc.format203-208-
Idioma: dc.languageen-
Relação: dc.relationArchives of Orthopaedic and Trauma Surgery-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectComputer-assisted surgery-
Palavras-chave: dc.subjectGenu varum-
Palavras-chave: dc.subjectHigh-tibial-osteotomy-
Palavras-chave: dc.subjectKnee osteoarthritis-
Palavras-chave: dc.subjectSurgical technique-
Título: dc.titleA novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric study-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.