Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.contributor | Federal Institute of Goiás (IFG) | - |
Autor(es): dc.creator | Morais, Douglas Carvalho [UNESP] | - |
Autor(es): dc.creator | Jose Mendes De Seixas, Falcondes [UNESP] | - |
Autor(es): dc.creator | Oro Arenas, Luis De [UNESP] | - |
Autor(es): dc.creator | Carvalho Souza, Lucas [UNESP] | - |
Autor(es): dc.creator | Souza Da Costa E Silva, Luciano De | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:25:43Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:25:43Z | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2020-12-11 | - |
Data de envio: dc.date.issued | 2019-11-30 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1109/COBEP/SPEC44138.2019.9065748 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/198848 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/198848 | - |
Descrição: dc.description | In this paper, a bridgeless buck-boost converter with power factor correction is proposed, using a three-state switching cell named of B configuration, operating in continuous conduction mode. The bridgeless technique allows the bridge rectifier inclusion switched on power grid frequency, in the high frequency DC-DC converter stage, reducing the stages number required and increasing the structure reliability. Due to three-state switching cell configuration, there is a current stress division by half of the inductor current in all of circuit semiconductors. Moreover, the ripple frequency on converter energy storage elements is twice switching frequency value, which make easier the design of input and output passive filters and reduces the converter's volume and weight. Preliminary simulation results prove the converter effectiveness on power factor correction, keeping output voltage stable in a specified operation point, with a total harmonic distortion of the input current less than 2%. | - |
Descrição: dc.description | São Paulo State University (UNESP) School of Engineering | - |
Descrição: dc.description | Federal Institute of Goiás (IFG) | - |
Descrição: dc.description | São Paulo State University (UNESP) School of Engineering | - |
Idioma: dc.language | en | - |
Relação: dc.relation | 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference, COBEP/SPEC 2019 | - |
???dc.source???: dc.source | Scopus | - |
Palavras-chave: dc.subject | bridgeless buck-boost converter | - |
Palavras-chave: dc.subject | continuous conduction mode | - |
Palavras-chave: dc.subject | power factor correction | - |
Palavras-chave: dc.subject | three-state switching cell | - |
Palavras-chave: dc.subject | total harmonic distortion | - |
Título: dc.title | Bridgeless Buck-Boost PFC Converter with Three-State Switching Cell | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: