Nd:YAG laser on dental enamel in the reduction of artificial caries demineralization

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorIPEN- Nuclear and Energy Research Institute-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorZezell, Denise M.-
Autor(es): dc.creatorSilva, Mateus R. [UNESP]-
Autor(es): dc.creatorCastro, Pedro A.A.-
Autor(es): dc.creatorSilva, Tânia M. [UNESP]-
Autor(es): dc.creatorGoncalves, Sergio E.P. [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:25:36Z-
Data de disponibilização: dc.date.available2022-02-22T00:25:36Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2019-01-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1117/12.2527213-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/198822-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/198822-
Descrição: dc.descriptionNd:YAG-laser associated to a photoabsorber, in the reduction of artificial caries in enamel was evaluated. Eighty bovine specimens with 6mm diameter and 2mm high were obtained and a half of the surface of each was protected as a control. Microdurometer and FTIR were performed initially and 8 groups (n=10) were obtained according to treatments: G1(control): no-treatment; G2(+control): fluorophosphate; G3(Nd:YAG 60mJ/pulse, 10Hz, 48J/cm2, non-contact); G4(photoabsorber + Nd:YAG 60mJ); G5(Nd:YAG 80mJ/pulse, 10Hz, 64J/cm2); G6(photoabsorber + Nd:YAG 80mJ); G7(Nd:YAG 100mJ/pulse, 10Hz, 80J/cm2); G8(photoabsorber + Nd:YAG 100mJ). De-remineralization cycle were performed for induction of artificial caries and to interferometer, microdurometer and FTIR. Microhardness data were submitted to 2-way ANOVA and Tukey/Dunnett tests 5%. Statistically differences were obtained in the photoabsorber-factor individually and in the interaction between laser and photoabsorber. There was a lower percentage of microhardness loss in the groups with photoabsorber; G8 presented microhardness similar to G2. FTIR data were submitted to T-test 5%. Compared with G2, higher concentrations of carbonate were found in G4, G6 and G8; phosphate in G8; lower Amide-I concentration at G8 and higher Carbonate/Phosphate ratio at G4 and G6. The interferometry results were submitted to 3-way ANOVA of repeated measures 5%. There were statistically differences in the photoabsorber-factor individually and in the time-factor. Photoabsorber decreased the demineralization; Nd:YAG-laser without photoabsorber were less effective than fluoride; Nd:YAG-laser 100mJ with photoabsorber was as effective as fluoride and; the Nd:YAG-laser, associated or not to the photoabsorber, was no more effective than fluoride in the reduction of artificial decay.-
Descrição: dc.descriptionIPEN- Nuclear and Energy Research Institute-
Descrição: dc.descriptionSão Paulo State University (UNESP) Institute of Science and Technology-
Descrição: dc.descriptionSão Paulo State University (UNESP) Institute of Science and Technology-
Idioma: dc.languageen-
Relação: dc.relationOptics InfoBase Conference Papers-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectCaries-
Palavras-chave: dc.subjectDemineralization-
Palavras-chave: dc.subjectEnamel-
Palavras-chave: dc.subjectLaser-
Palavras-chave: dc.subjectPhotoabsorber-
Título: dc.titleNd:YAG laser on dental enamel in the reduction of artificial caries demineralization-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.