Mechanical behavior of implant assisted removable partial denture for Kennedy class II

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.creatorTribst, João-Paulo-Mendes [UNESP]-
Autor(es): dc.creatorde Araújo, Rodrigo-Máximo [UNESP]-
Autor(es): dc.creatorRamanzine, Naiara-Pires [UNESP]-
Autor(es): dc.creatorSantos, Natália-Ribeiro [UNESP]-
Autor(es): dc.creatorde Oliveira Dal Piva, Amanda-Maria [UNESP]-
Autor(es): dc.creatorBorges, Alexandre-Luiz-Souto [UNESP]-
Autor(es): dc.creatorda Silva, João-Mauricio-Ferraz [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:25:32Z-
Data de disponibilização: dc.date.available2022-02-22T00:25:32Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2019-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.4317/MEDORAL.56533-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/198794-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/198794-
Descrição: dc.descriptionBackground: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants. Material and Methods: Four RPDs were manufactured for a Kennedy Class II: CRPD-Conventional RPD, RPD+ 1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to evaluate the microstrain. All groups were submitted to a retentive force analysis (0.5 mm/mm, 100kgf). Microstrain and retentive force data were submitted to One-way ANOVA and the Tukey test, all with α=5%. Results: High microstrain was observed in the second premolar adjacent to the edentulous space under compression load (p < 0.01). RPD+12M presented lower microstrain, however being similar to RPD+2M. RPD+1M presented a higher mean value of retentive force, but similar to RPD+12M. FEM showed RPD assisted by implants concentrates less stress in the periodontal ligament. The association of two implants was sufficient to decrease the stress generated in the implants. The most stressed region for the o-ring abutment was the threads, and the group with two implants showed the lowest stress concentration. Conclusions: In cases of Kennedy Class II, the association of RPD with implants in the molar region is a favorable option for patient rehabilitation, reducing the movement of the direct retainer adjacent to the edentulous space, increasing the removal force and decreasing the stress magnitude in the periodontal ligament.-
Descrição: dc.descriptionDepartment of Dental Materials and Proshodontics São Paulo State University (Unesp) Institute of Science and Technology-
Descrição: dc.descriptionSão Paulo State University (Unesp) Institute of Science and Technology-
Descrição: dc.descriptionDepartment of Dental Materials and Proshodontics São Paulo State University (Unesp) Institute of Science and Technology-
Descrição: dc.descriptionSão Paulo State University (Unesp) Institute of Science and Technology-
Formato: dc.formate38-e45-
Idioma: dc.languageen-
Relação: dc.relationJournal of Clinical and Experimental Dentistry-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDistal extension RPD considerations-
Palavras-chave: dc.subjectFinite element analysis-
Palavras-chave: dc.subjectImplant-assisted RPD-
Palavras-chave: dc.subjectProsthetic dentistry-
Palavras-chave: dc.subjectRemovable partial denture-
Título: dc.titleMechanical behavior of implant assisted removable partial denture for Kennedy class II-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.