Influence of implant connection on the stress distribution in restorations performed with hybrid abutments

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorAcademic Centre for Dentistry Amsterdam (ACTA)-
Autor(es): dc.contributorSanto Amaro University-
Autor(es): dc.creatorTribst, J. P.M. [UNESP]-
Autor(es): dc.creatorDal Piva, A. M.O. [UNESP]-
Autor(es): dc.creatorAnami, L. C.-
Autor(es): dc.creatorBorges, A. L.S. [UNESP]-
Autor(es): dc.creatorBottino, M. A. [UNESP]-
Data de aceite: dc.date.accessioned2022-02-22T00:24:52Z-
Data de disponibilização: dc.date.available2022-02-22T00:24:52Z-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2020-12-11-
Data de envio: dc.date.issued2019-09-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.23805/JO.2019.11.03.08-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/198541-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/198541-
Descrição: dc.descriptionAim This study evaluated the influence of prosthetic connection type (external hexagon [EH], internal hexagon [IH] and morse taper [MT]) on the stress distribution in an implant-supported prosthesis. Materials and methods Using modeling software, three sets were formed according to the prosthetic connection composed of ceramic crown, mesostructure, abutment, abutment screw, implant, cement layers and bone tissue. Solids were imported to the analysis software and bone model was fixed in the base. All materials were considered isotropic, linearly elastic and homogeneous. The static load (500 N, 30°) was applied in the central fossa. Stress distribution data were obtained according to Von-Mises and microstrain criteria. Results The type of prosthetic connection influenced the stress distribution. The stresses for the IH and MT connections were concentrated on the implant and abutment; for EH at the implant, abutment screw, at the implant platform, and at the cement layer between abutment and mesostructure. There is lower influence for the crown and mesostructure, with more promising results for the MT connection. For the bone tissue, all connections showed the same strain pattern. Stress peaks of 148, 142 and 138 MPa in the implant, 134, 129 and 62 MPa in the screw, and 86, 118 and 131 MPa were observed respectively for EH, IH and MT. Conclusions The morse taper connection showed promising performance with lower stress concentration in the abutment screw, implant platform and cement layers.-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology-
Descrição: dc.descriptionDepartment of Dental Materials Science Academic Centre for Dentistry Amsterdam (ACTA)-
Descrição: dc.descriptionDepartment of Dentistry Santo Amaro University-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology-
Formato: dc.format507-512-
Idioma: dc.languageen-
Relação: dc.relationJournal of Osseointegration-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectDentalimplant-abutment design-
Palavras-chave: dc.subjectFiniteelementanalysis-
Palavras-chave: dc.subjectKEYWORD Dentalimplants-
Título: dc.titleInfluence of implant connection on the stress distribution in restorations performed with hybrid abutments-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.