Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Univ Fed Parana | - |
Autor(es): dc.contributor | Athlone Inst Technol | - |
Autor(es): dc.contributor | Univ Tecnol Fed Parana | - |
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.creator | Pereira, Bruno Leandro | - |
Autor(es): dc.creator | Beilner, Gregory | - |
Autor(es): dc.creator | Lepienski, Carlos Mauricio | - |
Autor(es): dc.creator | Szameitat, Erico Saito | - |
Autor(es): dc.creator | Chee, Bor Shin | - |
Autor(es): dc.creator | Kuromoto, Neide Kazue | - |
Autor(es): dc.creator | Santos, Leonardo Luis dos | - |
Autor(es): dc.creator | Mazzaro, Irineu | - |
Autor(es): dc.creator | Rosifini Alves Claro, Ana Paula [UNESP] | - |
Autor(es): dc.creator | Nugent, Michael J. D. | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:09:42Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:09:42Z | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2020-01-24 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1016/j.surfcoat.2019.125224 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/196528 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/196528 | - |
Descrição: dc.description | Hydroxyapatite (HA) is a bioactive calcium phosphate capable of enhancing the implant/bone connection improving osteoconductivity and osseointegration process. However, the HA presents mechanical properties limiting its application. A good way to resolve this limitation is to combine the excellent biological properties of HA with materials with suitable mechanical behavior, like Ti-25Nb-25Ta alloy. The Ti-25Nb-25Ta alloy is cornposted by non-toxic and corrosion-resistant elements, presenting good biological compatibility. In this work, Plasma Electrolytic Oxidation (PEO) (using direct current-DC) was applied in conventional mode and Two-Step PEO aiming to produce a porous coating containing HA. It was not possible to produce a satisfactory coating applying conventional PEO due to successive spalling during the oxidation process. Adding a pretreatment to the conventional PEO changed the process to Two -Step PEO allowing to form a porous coating containing HA. The pretreatment was made by PEO using phosphoric electrolyte to produce a pre-coating. After that, the pre-coating was re-oxidized with calcium/phosphorus electrolyte. The Two -Step oxidized surface presented well-known good characteristics to applications in osseous implant devices such as porous formation, roughness in the micrometrical range, surface containing calcium and phosphorus, bioactive crystalline titanium oxide, and well adhered HA formation. However, the coating morphology and chemical composition of pre-coating and Two Step oxidized surfaces were not uniform. The non-uniformity of the Two -Step oxidized surface follows a similar non-uniformity pattern of the pre-coating surface. Two distinct morphologies were identified on the Two-Step oxidized surface: a velvety morphology with HA formation and a highly porous morphology. Regarding the Ti-25Nb-25Ta alloy, the Two-Step oxidation produced an adhered coating with porous apatite distribution interspersed with calcium-rich porous oxide. | - |
Descrição: dc.description | LORXI at UFPR, Brazil | - |
Descrição: dc.description | Univ Fed Parana, Postgrad Program Mat Engn & Sci PIPE, Curitiba, Parana, Brazil | - |
Descrição: dc.description | Athlone Inst Technol, MRI, Athlone, Ireland | - |
Descrição: dc.description | Univ Tecnol Fed Parana, Dept Mech Engn Curitiba, Curitiba, Parana, Brazil | - |
Descrição: dc.description | Univ Fed Parana, Dept Phys, Curitiba, PR, Brazil | - |
Descrição: dc.description | Univ Estadual Paulista, Dept Mat & Technol, Guaratingueta, SP, Brazil | - |
Descrição: dc.description | Univ Estadual Paulista, Dept Mat & Technol, Guaratingueta, SP, Brazil | - |
Descrição: dc.description | LORXI at UFPR, Brazil: FINEP CT-INFRA 793/2004 | - |
Descrição: dc.description | LORXI at UFPR, Brazil: 3080/2011 | - |
Formato: dc.format | 8 | - |
Idioma: dc.language | en | - |
Publicador: dc.publisher | Elsevier B.V. | - |
Relação: dc.relation | Surface & Coatings Technology | - |
???dc.source???: dc.source | Web of Science | - |
Palavras-chave: dc.subject | beta-Titanium alloys | - |
Palavras-chave: dc.subject | Ti-25Nb-25Ta | - |
Palavras-chave: dc.subject | Hydroxyapatite | - |
Palavras-chave: dc.subject | Two-Step PEO | - |
Palavras-chave: dc.subject | Nanoscratch test | - |
Título: dc.title | Oxide coating containing apatite formed on Ti-25Nb-25Ta alloy treated by Two-Step Plasma Electrolytic Oxidation | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: