Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.contributor | Univ Amsterdam | - |
Autor(es): dc.contributor | Vrije Univ | - |
Autor(es): dc.creator | Mendes Tribst, Joao Paulo [UNESP] | - |
Autor(es): dc.creator | Oliveira Dal Piva, Amanda Maria de [UNESP] | - |
Autor(es): dc.creator | Souto Borges, Alexandre Luiz [UNESP] | - |
Autor(es): dc.creator | Araujo, Rodrigo Maximo [UNESP] | - |
Autor(es): dc.creator | Ferraz da Silva, Joao Mauricio [UNESP] | - |
Autor(es): dc.creator | Bottino, Marco Antonio [UNESP] | - |
Autor(es): dc.creator | Kleverlaan, Cornelis Johannes | - |
Autor(es): dc.creator | Jager, Niek de | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:09:39Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:09:39Z | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2020-01-31 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1016/j.dental.2019.11.027 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/196514 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/196514 | - |
Descrição: dc.description | Objectives. This study aimed to evaluate the effect of different materials and undercut on the removal force and stress distribution in the supporting tooth and in the circumferential clasp used in removable partial prosthesis. Methods. Upper molars prepared for Akers circumferential clasp with retention and opposing arm were modeled, scanned, elaborated with CAD software and the geometries imported in FEA and analyzed. Six different materials were selected for the clasp (Polyamide, Poly-oxymethylene, Polyetheretherketone - PEEK, Gold alloy, Titanium and CoCr) and 3 different undercuts (0.25, 0.50 and 0.75 mm), totaling 18 groups. Results. The clasps presented greater stress in their structure and potentially greater damage to the dental enamel when made with rigid materials and with more undercut; however, they presented greater ability to remain in position. Significance. Polyamide with a higher undercut is an esthetic alternative to rigid metallic clasps. It showed promising behavior because it strongly reduces the damage to the enamel, and even with an undercut of 0.75, the retention is lower than for CoCr with a 0.25 undercut, and this retention might still be sufficient. Polyoxymethylene and Polyetheretherketone (PEEK) are not suitable materials for the clasps, because the maximum stress occurring during removal with higher undercuts is higher than the material strength. (C) 2019 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved. | - |
Descrição: dc.description | Sao Paulo State Univ Unesp, Inst Sci & Technol, PhD Grad Program Restorat Dent, Av Engn Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, SP, Brazil | - |
Descrição: dc.description | Univ Amsterdam, Acad Ctr Dent Amsterdam ACTA, Dept Dent Mat Sci, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands | - |
Descrição: dc.description | Vrije Univ, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland, Netherlands | - |
Descrição: dc.description | Sao Paulo State Univ Unesp, Inst Sci & Technol, PhD Grad Program Restorat Dent, Av Engn Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, SP, Brazil | - |
Formato: dc.format | 179-186 | - |
Idioma: dc.language | en | - |
Publicador: dc.publisher | Elsevier B.V. | - |
Relação: dc.relation | Dental Materials | - |
???dc.source???: dc.source | Web of Science | - |
Palavras-chave: dc.subject | Removable partial denture | - |
Palavras-chave: dc.subject | Finite element analysis | - |
Palavras-chave: dc.subject | Prosthetic dentistry | - |
Palavras-chave: dc.subject | Retentive force | - |
Palavras-chave: dc.subject | Clasp | - |
Palavras-chave: dc.subject | Non-Metal clasp | - |
Palavras-chave: dc.subject | Retention | - |
Título: dc.title | Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: