Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade Estadual de Campinas (UNICAMP) | - |
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.contributor | Univ Illinois | - |
Autor(es): dc.contributor | Rush Univ | - |
Autor(es): dc.creator | Ricardo Barao, Valentim Adelino [UNESP] | - |
Autor(es): dc.creator | Mathew, Mathew T. | - |
Autor(es): dc.creator | Yuan, Judy Chia-Chun | - |
Autor(es): dc.creator | Knoernschild, Kent L. | - |
Autor(es): dc.creator | Assuncao, Wirley Goncalves [UNESP] | - |
Autor(es): dc.creator | Wimmer, Markus A. | - |
Autor(es): dc.creator | Sukotjo, Cortino | - |
Data de aceite: dc.date.accessioned | 2022-02-22T00:06:56Z | - |
Data de disponibilização: dc.date.available | 2022-02-22T00:06:56Z | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2020-12-09 | - |
Data de envio: dc.date.issued | 2013-12-01 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/195814 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/195814 | - |
Descrição: dc.description | Statement of problem. Titanium is subject to corrosion in the oral cavity, which could contribute to periimplantitis. However, the effect of corrosion on the lipopolysaccharide affinity for titanium remains unknown. Purpose. This study evaluated the role of corrosion (in artificial saliva at pHs 3, 6.5, and 9) on the lipopolysaccharide (LPS) affinity for commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Material and methods. Seventy-two titanium disks were anodically polarized in a controlled environment (n=9). Control specimens were not corroded. Deionized water with different concentrations of LPS (1.5, 15, and 150 mu g/mL) were used to treat the disks for 24 hours to investigate LPS adherence (n=3). Then specimens were immersed in LPS-free water to evaluate LPS elution at 24, 48, and 72 hours. Data were analyzed by the 2-way, 3-way, and 3-way repeated measures ANOVA, t tests, and the Tukey honestly significant difference (HSD) tests (alpha=.05). Results. A greater corrosion rate of cp-Ti and Ti-6Al-4V alloy and a higher LPS adherence to titanium surfaces (P<.05) were noted at acidic pH. The LPS affinity was higher for the Ti-6Al-4V alloy than for cp-Ti (P<.05). More LPS was eluted from titanium surfaces after a 24-hour interval. Conclusion. Lipopolysaccharide affinity for cp-Ti and Ti-6Al-4V alloy is influenced by the corrosion process. | - |
Descrição: dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
Descrição: dc.description | International Association for Dental Research (IADR), Brazilian Division, Aguas de Lindoia, Brazil | - |
Descrição: dc.description | Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Sao Paulo, Brazil | - |
Descrição: dc.description | Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil | - |
Descrição: dc.description | Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL USA | - |
Descrição: dc.description | Univ Illinois, Coll Dent, Dept Restorat Dent, Adv Prosthodont, Chicago, IL USA | - |
Descrição: dc.description | Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA | - |
Descrição: dc.description | Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil | - |
Descrição: dc.description | CAPES: BEX4129/09-1 | - |
Formato: dc.format | 462-470 | - |
Idioma: dc.language | en | - |
Publicador: dc.publisher | Elsevier B.V. | - |
Relação: dc.relation | Journal Of Prosthetic Dentistry | - |
???dc.source???: dc.source | Web of Science | - |
Título: dc.title | INFLUENCE OF CORROSION ON LIPOPOLYSACCHARIDE AFFINITY FOR TWO DIFFERENT TITANIUM MATERIALS | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: