APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Federal do Rio de Janeiro (UFRJ)-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorTENARIS CONFAB-
Autor(es): dc.contributorPetrobras SA-
Autor(es): dc.contributorBAM-
Autor(es): dc.creatorOliveira, Davi F.-
Autor(es): dc.creatorMoreira, Edson V. [UNESP]-
Autor(es): dc.creatorSilva, Aline S. S.-
Autor(es): dc.creatorRabello, Jose M. B.-
Autor(es): dc.creatorLopes, Ricardo T.-
Autor(es): dc.creatorPereira, Marcelo S. [UNESP]-
Autor(es): dc.creatorZscherpel, Uwe-
Autor(es): dc.creatorInt Comm Non-Destructive Testing-
Data de aceite: dc.date.accessioned2022-02-22T00:04:00Z-
Data de disponibilização: dc.date.available2022-02-22T00:04:00Z-
Data de envio: dc.date.issued2020-12-09-
Data de envio: dc.date.issued2020-12-09-
Data de envio: dc.date.issued2010-01-01-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/194820-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/194820-
Descrição: dc.descriptionThe aim of this work is to evaluate the feasibility of the direct radiography on weld inspection in oil pipelines and gas pipeline during the manufacturing process. To that, 6 specimens with 6 different thickness and varied height of reinforced weld with 5 different kinds of defects were made. All samples were radiographied using Class I films and flat panel. For all specimens the inspection length was 8. Thus, with the flat panel the detector-to-object distance varied so that it may adequate to several diameters of the tubes. The detector-to-object distance was calculated based on the physical size of the detector taking into consideration a safe distance between the tube curvature and the flat panel extremities, keeping the lowest possible magnification factor so that it could be obtained the length of the inspection. Images with 6 integration time for each experimental arrangement were obtained. The images obtained with the Flat Panel/YXLON system were analyzed according to their quality by using the Contrast parameters (essential wire) (DNV 2007/ ISO 12096 - with reinforcement and ISO 10893-7 - basis material), Basic Spatial Resolution - BSR (ISO 10893-7) and normalized signal-to-noise ratio - SNRN (ISO 10893-7) and by detectability using as reference the conventional radiography. The results showed that for all thickness, the exposure time used to meet the image quality requirements were below with direct radiography. However the BSR were not reached for thickness of 4.85, 6.40 and 9.67 mm, therefore the compensation principle established, by ISO 10893-7 was considered, that is, one more contrast wire for a less wire pair. The digital technique proved to be more sensitive to real defects found on welds than the conventional technique. Then it can be conclude that the digital radiography utilizing the flat panel can be applicable to the oil and gas segment with advantages over conventional technique as to quality aspects, productivity, environment, safety and health.-
Descrição: dc.descriptionUniv Fed Rio de Janeiro, COPPE, Nucl Instrumentat Lab, Rio de Janeiro, RJ, Brazil-
Descrição: dc.descriptionUniv Estadual Paulista, Mat & Technol Dept, Sao Paulo, SP, Brazil-
Descrição: dc.descriptionTENARIS CONFAB, Pindamonhangaba, SP, Brazil-
Descrição: dc.descriptionPetrobras SA, SEQUI, Rio De Janeiro, RJ, Brazil-
Descrição: dc.descriptionBAM, Fed Inst Mat Res & Testing, Stuttgart, Germany-
Descrição: dc.descriptionUniv Estadual Paulista, Mat & Technol Dept, Sao Paulo, SP, Brazil-
Formato: dc.format993-1003-
Idioma: dc.languageen-
Publicador: dc.publisherInt Committee Non-destructive Testing-
Relação: dc.relation10th European Conference On Non-destructive Testing 2010 (ecndt), Vols 1-5-
???dc.source???: dc.sourceWeb of Science-
Título: dc.titleAPPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.