Versatile ultrasonic spectrometer for liquids with practical sample handling by using standard cuvettes

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFederal University of Ouro Preto-
Autor(es): dc.contributorUniversidade Estadual Paulista (Unesp)-
Autor(es): dc.contributorInstituto de Tecnologías Físicas y de la Información-
Autor(es): dc.contributorUniversidade Federal de Mato Grosso do Sul (UFMS)-
Autor(es): dc.creatorTiago, Marcelo Moreira-
Autor(es): dc.creatorHiguti, Ricardo Tokio [UNESP]-
Autor(es): dc.creatorSegura, Luis Elvira-
Autor(es): dc.creatorKitano, Claudio [UNESP]-
Autor(es): dc.creatorAssuncao, Edvaldo [UNESP]-
Autor(es): dc.creatorOliveira, Samuel L.-
Data de aceite: dc.date.accessioned2022-02-21T23:51:56Z-
Data de disponibilização: dc.date.available2022-02-21T23:51:56Z-
Data de envio: dc.date.issued2019-10-06-
Data de envio: dc.date.issued2019-10-06-
Data de envio: dc.date.issued2019-01-01-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1109/TUFFC.2018.2875872-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/188222-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/188222-
Descrição: dc.descriptionThis work describes the development and tests of a new ultrasonic spectrometer for liquids based on the use of commercial cuvettes for sample handling. The spectrometer operates in the frequency range from 20 to 80 MHz and gathers some important characteristics, which are its high thermal stability (better than 0.01 °C), by the use of Peltier cells, and practical sample handling with small volume (≤3 ml) samples placed inside cuvettes which can be easily removed from the spectrometer, cleaned/sterilized, or simply discarded. Through-transmission operation is used to measure propagation velocity and attenuation coefficient, and the spectrometer was tested with mixtures of water and NaCl, which have attenuations smaller than that of distilled water, and higher attenuation samples of silicone and castor oil. Backscattering studies of polystyrene particles of 10-and 15-μ m diameters were also conducted, showing the versatility of the instrument.-
Descrição: dc.descriptionDepartment of Electrical Engineering Institute of Exact and Applied Sciences Federal University of Ouro Preto-
Descrição: dc.descriptionDepartment of Electrical Engineering School of Engineering Univ Estadual Paulista UNESP Campus of Ilha Solteira-
Descrição: dc.descriptionCSIC Instituto de Tecnologías Físicas y de la Información-
Descrição: dc.descriptionInstitute of Physics Universidade Federal de Mato Grosso Do sul-
Descrição: dc.descriptionDepartment of Electrical Engineering School of Engineering Univ Estadual Paulista UNESP Campus of Ilha Solteira-
Formato: dc.format109-118-
Idioma: dc.languageen-
Relação: dc.relationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control-
Direitos: dc.rightsAcesso aberto-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectAttenuation-
Palavras-chave: dc.subjectBackscattering-
Palavras-chave: dc.subjectCuvettes-
Palavras-chave: dc.subjectPropagation velocity-
Palavras-chave: dc.subjectUltrasonic spectrometer-
Palavras-chave: dc.subjectWater and NaCl mixtures-
Título: dc.titleVersatile ultrasonic spectrometer for liquids with practical sample handling by using standard cuvettes-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.