Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Universidade de São Paulo (USP) | - |
Autor(es): dc.contributor | Universidade Estadual Paulista (Unesp) | - |
Autor(es): dc.creator | Edwards Rezende, Carlos Eduardo | - |
Autor(es): dc.creator | Chase-Diaz, Melody | - |
Autor(es): dc.creator | Costa, Max Doria | - |
Autor(es): dc.creator | Albarracin, Max Laurent | - |
Autor(es): dc.creator | Paschoeto, Gabriela [UNESP] | - |
Autor(es): dc.creator | Capello Sousa, Edson Antonio [UNESP] | - |
Autor(es): dc.creator | Rubo, Jose Henrique | - |
Autor(es): dc.creator | Sanches Borges, Ana Flavia | - |
Data de aceite: dc.date.accessioned | 2022-02-21T23:07:57Z | - |
Data de disponibilização: dc.date.available | 2022-02-21T23:07:57Z | - |
Data de envio: dc.date.issued | 2018-11-27 | - |
Data de envio: dc.date.issued | 2018-11-27 | - |
Data de envio: dc.date.issued | 2015-10-01 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1097/SCS.0000000000001977 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/11449/165030 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/11449/165030 | - |
Descrição: dc.description | This study aimed to analyze the stress distribution in single implant system and to evaluate the compatibility of an in vitro model with finite element (FE) model. The in vitro model consisted of Branemark implant; multiunit set abutment of 5mm height; metal-ceramic screw-retained crown, and polyurethane simulating the bone. Deformations were recorded in the peri-implant region in the mesial and distal aspects, after an axial 300N load application at the center of the occlusal aspect of the crown, using strain gauges. This in vitro model was scanned with micro CT to design a three-dimensional FE model and the strains in the peri-implant bone region were registered to check the compatibility between both models. The FE model was used to evaluate stress distribution in different parts of the system. The values obtained from the in vitro model (20-587 epsilon) and the finite element analysis (81-588 epsilon) showed agreement among them. The highest stresses because of axial and oblique load, respectively were 5.83 and 40MPa for the cortical bone, 55 and 1200MPa for the implant, and 80 and 470MPa for the abutment screw. The FE method proved to be effective for evaluating the deformation around single implant. Oblique loads lead to higher stress concentrations. | - |
Descrição: dc.description | Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont, BR-05508 Sao Paulo, Brazil | - |
Descrição: dc.description | Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, BR-05508 Sao Paulo, Brazil | - |
Descrição: dc.description | Sao Paulo State Univ, Sch Engn, Dept Mech Engn, Sao Paulo, Brazil | - |
Descrição: dc.description | Sao Paulo State Univ, Sch Engn, Dept Mech Engn, Sao Paulo, Brazil | - |
Formato: dc.format | 2196-2200 | - |
Idioma: dc.language | en | - |
Publicador: dc.publisher | Lippincott Williams & Wilkins | - |
Relação: dc.relation | Journal Of Craniofacial Surgery | - |
Relação: dc.relation | 0,448 | - |
Direitos: dc.rights | Acesso restrito | - |
???dc.source???: dc.source | Web of Science | - |
Palavras-chave: dc.subject | Dental implants | - |
Palavras-chave: dc.subject | dental prostheses | - |
Palavras-chave: dc.subject | finite element analysis | - |
Título: dc.title | Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Unesp |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: