Implementação de um instrumento para medição da intensidade de fótons na faixa da mamografia

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorAndreazzi, Mariana-
Data de aceite: dc.date.accessioned2021-03-10T23:28:58Z-
Data de disponibilização: dc.date.available2021-03-10T23:28:58Z-
Data de envio: dc.date.issued2018-04-18-
Data de envio: dc.date.issued2018-04-18-
Data de envio: dc.date.issued2018-02-07-
Fonte completa do material: dc.identifierhttp://hdl.handle.net/11449/153596-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/153596-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
Descrição: dc.descriptionPós-graduação em Engenharia Elétrica - FEIS-
Descrição: dc.descriptionFoi implementado um instrumento com a finalidade de medir a intensidade (taxa de fluência de energia) de fótons na faixa de mamografia (22 a 33 kVp) e a tensão do tubo de um mamógrafo. O instrumento é constituído por uma câmara com sensor piroelétrico de metaniobato de chumbo (PbNb2¬O¬¬6) e seu circuito de condicionamento de sinais. Utilizou-se poliácido lático para confeccionar a câmara piroelétrica em uma impressora 3D. O circuito de condicionamento de sinais é um conversor corrente-tensão de alta sensibilidade. A intensidade da radiação foi determinada a partir da taxa de exposição medida com uma câmara de ionização. Uma simulação do espectro de emissão do molibdênio, na faixa de 22 a 33 kVp, foi realizada com o sensor piroelétrico e o software DTSA-II, e comparada com a o feita com um sensor de Si(Li), comumente empregado. Os resultados obtidos mostram que a resposta do instrumento implementado é linear com a tensão do tubo de raios-X e com a intensidade da radiação, e que o espectro de emissão do molibdênio pode ser determinado com o instrumento piroelétrico.-
Descrição: dc.descriptionAn instrument to measure the intensity (energy fluence rate) of photons in the mammography range (22 to 33 kVp) and the tube voltage of a mammograph. The instrument consists of a chamber with a pyroelectric sensor of lead methaniobate (PbNb2O6) and its signal conditioning circuit. Polyacid was used to make the pyroelectric chamber in a 3D printer. The signal conditioning circuit is a high sensitivity current-voltage converter. The intensity of the radiation was determined from the exposure rate measured with an ionization chamber. A simulation of the emission spectrum for molybdenum, in the range of 22 to 33 kVp, was performed with the pyroelectric sensor and the DTSA-II software, and compared to that simulated using the commonly used Si (Li) sensor. The results show that the response of the implemented instrument is linear with the X-ray tube voltage and the intensity of the radiation, and that the emission spectrum of molybdenum can be determined with a pyroelectric instrument.-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsopenAccess-
Palavras-chave: dc.subjectSensor piroelétrico-
Palavras-chave: dc.subjectMamografia-
Palavras-chave: dc.subjectTaxa de fluência de energia-
Palavras-chave: dc.subjectRaios-X-
Palavras-chave: dc.subjectDosimetria-
Palavras-chave: dc.subjectSimulação de raios-X-
Palavras-chave: dc.subjectPyroelectric sensor-
Palavras-chave: dc.subjectMammography-
Palavras-chave: dc.subjectEnergy fluency rate-
Palavras-chave: dc.subjectX ray-
Palavras-chave: dc.subjectDosimetry-
Palavras-chave: dc.subjectSimulation of X-rays-
Título: dc.titleImplementação de um instrumento para medição da intensidade de fótons na faixa da mamografia-