Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
???dc.contributor.advisor???: dc.contributor.advisor | Paz, Mário Arlindo Irrigaray | - |
Autor(es): dc.contributor.author | Lorenzon, Andressa | - |
Data de aceite: dc.date.accessioned | 2014-04-02T14:07:20Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T14:38:53Z | - |
Data de disponibilização: dc.date.available | 2014-04-02T14:07:20Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T14:38:53Z | - |
Data de envio: dc.date.issued | 2014-04-02 | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/1970 | - |
???dc.identifier.citation???: dc.identifier.citation | LORENZON, Andressa. Análise da resistência residual do concreto após exposição a altas temperaturas. 2014. 57 f. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Pato Branco, 2014. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/170434 | - |
Resumo: dc.description.abstract | The concrete is known to has a good performance against high temperatures, since it has low thermal conductivity , is non- combustible and will not be release toxic gases . However , due to the heterogeneous composition of the material when exposed to situations such as fires , undergoes physical , chemical and mechanical changes that can compromise its structural integrity . Aiming to analyze the residual strength of concrete subjected to high temperatures, were performed uniaxial compression tests on bodies -specimens submitted to different temperatures ( 300 º C , 500 º C and 900 º C ) , exposure times ( 30 , 60 and 90 minutes) and cooling modes ( slow cooling and sudden cooling ) . The dosage was realizadada in order to meet the requirements of NBR 6118 and NBR 12655 , which proposed minimum values of water / cement ratio for concrete can meet the durability requirements of aggression exposed to strong structures . Afforded a concrete mix of 1 : 1.06 : 1.06 : 2.87 : 0.55 ( cement : sand natural , artificial sand : aggregates : water) to a characteristic resistance ( fck ) of 25 MPa. 76 bodies of the specimen of 5 cm in diameter and 10 cm high, exposed to fire conditions and broken after 7 days of curing were molded . For temperatures up to 300 ° C concrete presented losses of up to 40 % of initial strength , which increased to 50% at temperatures up to 500 º C, until a reduction from 80% to 90 % of the resistance to temperatures of 800 ° C. Furthermore , it was shown that the sudden cooling causes more damage to the concrete than the slow cooling , but there were few variations. | pt_BR |
Palavras-chave: dc.subject | Resistência de materiais | pt_BR |
Palavras-chave: dc.subject | Concreto - Efeito da temperatura | pt_BR |
Palavras-chave: dc.subject | Concreto - Testes | pt_BR |
Palavras-chave: dc.subject | Strength of materials | pt_BR |
Palavras-chave: dc.subject | Concrete - Effect of temperature on | pt_BR |
Palavras-chave: dc.subject | Concrete - Testing | pt_BR |
Título: dc.title | Análise da resistência residual do concreto após exposição a altas temperaturas | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: